Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography.

نویسندگان

  • Omar K Khalique
  • Susheel K Kodali
  • Jean-Michel Paradis
  • Tamim M Nazif
  • Mathew R Williams
  • Andrew J Einstein
  • Gregory D Pearson
  • Kishore Harjai
  • Kendra Grubb
  • Isaac George
  • Martin B Leon
  • Rebecca T Hahn
چکیده

BACKGROUND Previous studies have shown cross-sectional 3-dimensional (3D) transesophageal echocardiographic (TEE) measurements to severely underestimate multidetector row computed tomographic (MDCT) measurements for the assessment of aortic annulus before transcatheter aortic valve replacement. This study compares annulus measurements from 3D-TEE using off-label use of commercially available software with MDCT measurements and assesses their ability to predict paravalvular regurgitation. METHODS AND RESULTS One hundred patients with severe, symptomatic aortic stenosis who had both contrast MDCT and 3D-TEE for annulus assessment before balloon-expandable transcatheter aortic valve replacement were analyzed. Annulus area, perimeter, and orthogonal maximum and minimum diameters were measured. Receiver operating characteristic analysis was performed with mild or greater paravalvular regurgitation as the classification variable. Three-dimensional TEE and MDCT cross-sectional perimeter and area measurements were strongly correlated (r=0.93-0.94; P<0.0001); however, the small differences (≤1%) were statistically significant (P=0.0002 and 0.0074, respectively). Discriminatory ability for ≥ mild paravalvular regurgitation was good for both MDCT (area under the curve for perimeter and area cover index=0.715 and 0.709, respectively) and 3D-TEE (area under the curve for perimeter and area cover index=0.709 and 0.694, respectively). Differences in receiver operating characteristic analysis between MDCT and 3D-TEE perimeter and area cover indexes were not statistically significant (P=0.15 and 0.35, respectively). CONCLUSIONS Annulus measurements using a new method for analyzing 3D-TEE images closely approximate those of MDCT. Annulus measurements from both modalities predict mild or greater paravalvular regurgitation with equivalent accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic annulus sizing: echocardiographic versus computed tomography derived measurements in comparison with direct surgical sizing.

OBJECTIVES The precise sizing of the aortic annulus is crucial in order to select the most appropriate valve size for transcatheter aortic valve implantation (TAVI). Owing to the closed heart situation in TAVI, sizing has to be performed based on preoperative imaging when compared with direct sizing during conventional procedures. The aim of the study was to evaluate valve sizing performed eith...

متن کامل

Relationship of Annular Sizing Using Multidetector Computed Tomographic Imaging and Clinical Outcomes After Self-Expanding CoreValve Transcatheter Aortic Valve Replacement.

BACKGROUND Multidetector computed tomography is useful for determining the appropriate transcatheter heart valve (THV) size in patients with severe aortic stenosis who are suboptimal surgical candidates. The relationship between adherence to the recommended CoreValve sizing algorithm and clinical outcomes is not known. METHODS AND RESULTS We evaluated 1023 patients with severe aortic stenosis...

متن کامل

Valve sizing for pure aortic regurgitation during transcatheter aortic valve replacement: deformation dynamic of the aortic annulus in different valve pathology may be different.

We read with great interest the report by Seiffert et al. (1) on the initial German experience with transapical implantation of a second-generation transcatheter heart valve for the treatment of aortic regurgitation. With the development of second-generation transcatheter aortic value replacement (TAVR) devices, TAVR indications have been expended to high-risk patients with pure aortic regurgit...

متن کامل

Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography.

OBJECTIVES This study compared cross-sectional three-dimensional (3D) transesophageal echocardiography (TEE) to two-dimensional (2D) TEE as methods for predicting aortic regurgitation after transcatheter aortic valve replacement (TAVR). BACKGROUND Data have shown that TAVR sizing using cross-sectional contrast computed tomography (CT) parameters is superior to 2D-TEE for the prediction of par...

متن کامل

Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve.

OBJECTIVES The aim of this study was to demonstrate the first-in-human feasibility and short-term clinical outcomes with a new balloon-expandable transcatheter heart valve (THV). BACKGROUND The SAPIEN 3 (S3) THV incorporates a paravalvular sealing system, an active 3-dimensional coaxial positioning catheter, and is compatible with a 14-F expandable sheath. METHODS The S3 THV was implanted i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 7 1  شماره 

صفحات  -

تاریخ انتشار 2014