Measurement by venous occlusion plethysmography of blood flow through surgically created arteriovenous fistulae in the human forearm.

نویسندگان

  • W F Wallace
  • J P Jamison
چکیده

1. Plethysmographs containing the hand plus forearm were used to measure blood flow in patients with a srugically created arteriovenous fistula in one forearm. 2. Apparent flow rate was stable over a limited range of collecting pressures; the absolute value of these pressures varied from patient to patient. 3. After arterial occlusion, blood flow increased by a similar amount on the normal side and on the side with the fistula. 4. Occlusion of fistular flow produced no significant change in heart rate. 5. Fistular flow, estimated as the difference between flow on the two sides, averaged 525 ml/min in seventeen patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radionuclide plethysmography for noninvasive evaluation of peripheral arterial blood flow.

We validated a noninvasive radionuclide plethysmography technique to evaluate peripheral arterial blood flow during reactive hyperemia. This method, based on the measurement of blood volume variations during repetitive venous occlusions, was compared with strain-gauge venous impedance plethysmography. The technique uses 99mTc-labeled autologous red blood cells scintigraphy to determine the rate...

متن کامل

Reactive Hyperemia in Human Forearm Vessels

Background The role of nitric oxide (NO) in reactive hyperemia (RH) is not well known. We investigated whether NO plays a role in RH in human forearm vessels by examining the effects of N0-monomethyl-L-arginine (L-NMMA), a blocker of NO synthesis, on reactive hyperemic flow. Methods and Results Forearm blood flow (FBF) was measured by strain-gauge plethysmography with a venous occlusion techniq...

متن کامل

Human Forearm Vessels

Background The role of nitric oxide (NO) in reactive hyperemia (RH) is not well known. We investigated whether NO plays a role in RH in human forearm vessels by examining the effects of N0-monomethyl-L-arginine (L-NMMA), a blocker of NO synthesis, on reactive hyperemic flow. Methods and Results Forearm blood flow (FBF) was measured by strain-gauge plethysmography with a venous occlusion techniq...

متن کامل

Reproducibility of blood flow and post-occlusive reactive hyperaemia as measured by venous occlusion plethysmography.

Venous occlusion plethysmography is commonly used as a tool to assess BF (blood flow) and VR (vascular resistance) at baseline and during PORH (post-occlusive reactive hyperaemia). However, little is known about the reproducibility of this method. The purpose of the present study was to investigate short- (hours) and medium (week)-term reproducibility of forearm, calf and thigh BF and VR at bas...

متن کامل

Venous occlusion pressure plethysmography in the human upper limb.

Two techniques of venous occlusion pressure plethysmography were examined experimentally in the human upper limb. The first was the classical method, in which external pressure is applied to the limb solely by way of the plethysmograph. In the second, the entire upper limb including the plethysmograph and venous occlusion cuff was enclosed in a box within which the air pressure could be raised....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical science and molecular medicine

دوره 50 1  شماره 

صفحات  -

تاریخ انتشار 1976