A biomechanical analysis of a tensioned suture device in the fixation of the ligamentous Lisfranc injury.
نویسندگان
چکیده
BACKGROUND We hypothesized that using a cadaveric Lisfranc ligamentous injury model, abduction stress would provoke greater post-injury motion than axial weightbearing between the medial cuneiform (MC1) and the base of the second metatarsal (MT2). Second, we hypothesized that both a tensioned suture-button device and a rigid screw fixation method could maintain a reduction and similarly restrain motion to intact (pre-injury) levels. MATERIALS AND METHODS Motion was measured between MC1 and MT2 in five matched pairs of human cadaveric feet. Specimens were tested prior to injury, following a transverse ligamentous Lisfranc injury, and then randomized to either screw or tensioned suture-button fixation. Axial then abduction loads were applied. Measurements were repeated after one thousand loading cycles. RESULTS With both axial and abduction loads, statistically significant differences in motion were detected between the intact and post-injury conditions, although the magnitudes were greater with abduction (6.8 mm versus 2.0 mm, p = 0.000004). With abduction loads, both fixation methods were effective in restraining motion to pre-injury levels (screw fixation: 1.5 mm intact versus 1.1 mm post-fixation, p = 0.487; suture-button fixation: 1.3 mm intact versus 2.1 mm post-fixation, p = 0.063), and similarly, both devices restrained motion to less than post-injury levels (screw fixation: 8.1 mm post-injury versus 1.1 mm post-fixation, p = 0.001; suture-button fixation: mean 5.5 mm post-injury versus 2.1 mm post-fixation, p = 0.0002). No significant differences in these patterns were detected following cyclic loading. CONCLUSION Small, though statistically significant, amounts of motion are produced between MC1 and MT2 with axial loading after a ligamentous Lisfranc injury. With abduction stress, we were able to show a significantly greater difference between pre- and post-injury motion and the ability of both fixation methods to restrain motion to pre-injury levels. CLINICAL RELEVANCE Abduction stress may be valuable when diagnosing and testing the transverse ligamentous Lisfranc injury. Both suture-button and screw fixation methods restrain motion at the Lisfranc complex.
منابع مشابه
Ligamentous restraints of the second tarsometatarsal joint: a biomechanical evaluation.
Ligamentous injury of the tarsometatarsal joint complex is an uncommon, but disabling condition that frequently occurs in elite athletes. There are few options for managing these injuries, in part because the relative mechanical contribution of the ligaments of the tarsometatarsal joint is unknown, complicating decisions regarding which ligaments need reconstruction. In the current study, stren...
متن کاملOutcome after open reduction and internal fixation of Lisfranc joint injuries.
BACKGROUND Open reduction and internal fixation has been recommended as the treatment for most unstable injuries of the Lisfranc (tarsometatarsal) joint. It has been thought that purely ligamentous injuries have a poor outcome despite such surgical management. METHODS We performed a retrospective study of patients who underwent open reduction and screw fixation of a Lisfranc injury in a seven...
متن کاملA Novel Suture Button Construct for Acute Ankle Syndesmotic Injuries; A Prospective Clinical and Radiological Analysis.
Background: The importance of the syndesmosis in ankle stability is well recognized. Numerous means of fixation have been described for syndesmotic injuries including the suture button technique. Significant cost limits the use the commercially available options. We, therefore, designed a cheap and readily available alternative construct. We aim to assess the results of using a novel suture-...
متن کاملبررسی استئو آرتریت به دنبال جا اندازی باز و فیکساسیون داخلی
Background: Open reduction and internal fixation is the standard surgical approach for lisfranc fracture, however, osteoarthritis is a long term complication. We surveyed the frequency of osteoarthritis after open reduction and internal fixation of lisfranc fracture and its associated factors including accompanied fracture, delayed diagnosis and open or closed fracture. Materials and methods: ...
متن کاملBiomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Foot & ankle international
دوره 32 4 شماره
صفحات -
تاریخ انتشار 2011