Leadless Pacemaker: a New Concept in Cardiac Pacing
نویسندگان
چکیده
DOI: 10.5935/abc.20160144 67 year-old female patient, pacemaker user since 1983 due to complete atrioventricular block. Between 1991 and 2004, the patient underwent six surgeries. The first was to replace the batteries, and the others for electrode displacement, generator extrusion, and finally for endocarditis, when surgical extraction of the system and epicardial electrode implantation in the right ventricle (RV) were performed. In the last assessment, in 2015, the patient presented with a very high ventricular stimulation threshold and battery depletion. Due to previous technical problems, implantation of transvenous leadless pacemaker was considered (Micra-Medtronic). This new cardiac stimulation system has, as its main characteristics, reduced generator size (volume of 0.8 cm3) and the absence of electrodes, making it possible to perform the implantation of the system directly in the RV. Implantation was performed at Hospital Santa Cruz, Carnaxide, Portugal. After local anesthesia, a sheath (23F) was introduced through the right femoral vein to take the system to the RV. Once inside the ventricle, the delivery catheter was directed to the septal and apical portion and the capsule was released. Fixation of the system in the right ventricle trabeculae, through its flexible tines, was confirmed by mechanical fixation tests. After that, electronic assessment was performed yielding good parameters. After ensuring that parameters were adequate and the capsule was well fixated, the capsule was released and the delivery system was removed. The patient did not present any immediate complications, and after 45 days of follow-up, electronic parameters were stable.
منابع مشابه
Recent Advances in Pacing and Defibrillation
Most current pacemaker and ICD systems involve placement of lead(s) transvenously into the heart, connected to a pulse generator. Vascular access may be difficult or limited in some patients, and intravascular leads can be associated with multiple complications such as infection, lead malfunction and vascular occlusion. Recent advances in pacing and ICDs include the development of subcutaneous ...
متن کاملRetrieval of the Leadless Cardiac Pacemaker
Leadless cardiac pacemakers (LPs) have emerged as a safe and effective alternative to conventional transvenous pacemakers for patients with an indication for single-chamber ventricular pacing. In 2 prospective studies with intermediate follow-up, leadless pacemakers exhibited high acute implantation success rates and stable pacing performance at 6 months. Despite these promising results, the ab...
متن کاملECGs and Pacemakers
Leadless pacemakers will most likely be the future of cardiac pacing. Leadless pacing employs a singlechamber system to pace only the right ventricle and is fully self-contained, which eliminates the need for leads. These systems, implanted by using a transcatheter sheath, are indicated for patients who need right ventricular pacing only. These devices enable patients to avoid lead-related comp...
متن کاملFeasibility of Leadless Cardiac Pacing Using Injectable Magnetic Microparticles
A noninvasive, effective approach for immediate and painless heart pacing would have invaluable implications in several clinical scenarios. Here we present a novel strategy that utilizes the well-known mechano-electric feedback of the heart to evoke cardiac pacing, while relying on magnetic microparticles as leadless mechanical stimulators. We demonstrate that after localizing intravenously-inj...
متن کاملPermanent leadless cardiac pacing: results of the LEADLESS trial.
BACKGROUND Conventional cardiac pacemakers are associated with several potential short- and long-term complications related to either the transvenous lead or subcutaneous pulse generator. We tested the safety and clinical performance of a novel, completely self-contained leadless cardiac pacemaker. METHODS AND RESULTS The primary safety end point was freedom from complications at 90 days. Sec...
متن کاملState of the art of leadless pacing.
Despite undisputable benefits, conventional pacemaker therapy is associated with specific complications related to the subcutaneous device and the transvenous leads. Recently, two miniaturized leadless pacemakers, Nanostim™ (St. Jude Medical) and Micra™ (Medtronic), which can be completely implanted inside the right ventricle using steerable delivery systems, entered clinical application. The W...