Katariina Tuohimäki Electrocardiogram and Impedance Pneumography Measurement Module Design for Textile-integrated Solution
نویسنده
چکیده
KATARIINA TUOHIMÄKI: Electrocardiogram and Impedance Pneumography Measurement Module Design for Textile-Integrated Solution Tampere University of Technology Master of Science Thesis, 52 pages, 1 Appendix page July 2016 Master’s Degree Programme in Electrical Engineering Major: Biomedical instrumentation Examiners: Assoc. Prof. Matti Mäntysalo, Prof. Jari Viik
منابع مشابه
Comparison of Acoustic Respiration Rate, Impedance Pneumography and Capnometry Monitors for Respiration Rate Accuracy and Apnea Detection during GI Endoscopy Anesthesia
Study Objective: To assess the accuracy of respiration rate measurements and the ability to detect apnea by capnometry, impedance pneumography and a new method, acoustic respiration rate monitoring, in anesthetized patients undergoing gastrointestinal endoscopy procedures. Design: Prospective observational study. Setting: Endoscopy procedures laboratory. Patients: 98 patients scheduled for uppe...
متن کاملRespiration Rate Measurement Based on Impedance Pneumography
This document discusses the use of impedance pneumography as a technique to measure respiration rate. The generation of high-frequency ac current source is described, and the issues related to delay in modulated signal and finite transition times of carriers are addressed. The report also includes descriptions of potential implementations of a respiration rate measurement system using the ADS12...
متن کاملMilla Jauhiainen Validation of Impedance Pneumography Measure- Ment for Assessment of Respiration in Cardiotho- Racic Surgery Patients
MILLA JAUHIAINEN: Validation of Impedance Pneumography Measurement for Assessment of Respiration in Cardiothoracic Surgery Patients Tampere University of Technology Master of Science Thesis, 50 pages May 2017 Master’s Degree Programme in Electrical Engineering Major: Biomedical Engineering Examiners: Associate Professor Jari Viik and Professor Jari Hyttinen Place of work: Biomedical Sciences an...
متن کاملDoes asthma-like increased breathing load influence impedance pneumography signal?
Asthma is a chronic disease characterized by recurrent attacks of breathlessness and wheezing. During an asthma attack, a bronchospasm occurs. In order to overcome increased resistance of airways forced breathing is necessary. It affects the intrapleural pressure, blood volume within the thoracic cavity and therefore it may affect also impedance pneumography signal. We tried to imitate asthma-l...
متن کاملRespiratory Monitoring: Advantages of Inductive Plethysmography over Impedance Pneumography
Inductive plethysmography and impedance pneumography are two non-invasive technologies for measuring respiratory function. The following report describes the advantages of inductive plethysmography, which include greater accuracy and sensitivity; the ability to assess thoracoabdominal coordination; and the minimization of motion artifact. Together, these properties make inductive plethysmograph...
متن کامل