The measurement of carboxyhemoglobin and methemoglobin using a non-invasive pulse CO-oximeter.

نویسندگان

  • Cédrick Zaouter
  • Gerald S Zavorsky
چکیده

The pulse CO-oximeter (Rad-57 Masimo Corporation, Irvine, CA) allows non-invasive and instantaneous measurement of carboxyhemoglobin (COHb) and methemoglobin (MetHb) percentage level using a finger probe. However, the accuracy and reliability of the Rad-57 against the gold standard of venous or arterial blood samples have not been clearly established. Thus, the objective of this trial is to evaluate the accuracy and precision of the Rad-57 pulse CO-oximeter by comparing it with venous sampling on the same subjects. Nine healthy subjects were subjected to carbon monoxide such that it raised the COHb to 10-14% on two different days and pooled together. The COHb and MetHb were measured with a blood gas-analyzer and simultaneously with the Rad-57 as the COHb increased from 1.4 to 14%. Results were compared using linear regression and a Bland and Altman method comparison. Mean bias and precision for COHb measured with the Rad-57 was -1% and 2.5%, respectively. The mean bias and precision for MetHb measured with the Rad-57 was 0.0% and 0.3%, respectively. The ability to detect a COHb ≥ 10% occurred in 54% of the samples in which COHb was ≥ 10-14%. In conclusion, the Rad-57 provides a reading that is between -6% and +4% of the true COHb value for 95% of all samples. The Rad-57 seems to be a good substitute as a first screening test of COHb when the pulse CO-oximeter reads <15%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive measurements of carboxyhemoglobin and methemoglobin in children with sickle cell disease.

Assessment of oxyhemoglobin saturation in patients with sickle cell disease (SCD) is vital for prompt recognition of hypoxemia. The accuracy of pulse oximeter measurements of blood oxygenation in SCD patients is variable, partially due to carboxyhemoglobin (COHb) and methemoglobin (MetHb), which decrease the oxygen content of blood. This study evaluated the accuracy and reliability of a non-inv...

متن کامل

Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study.

BACKGROUND A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. METHODS Ten volunteers breathed 50...

متن کامل

Anxiety disorders in patients with COPD.

partment patients. Respir Care 2013;57(2): 232-240. 2. Touger M, Birnbaum A, Wang J, Chou K, Pearson D, Bijur P. Performance of the RAD-57 pulse CO-oximeter compared with standard laboratory carboxyhemoglobin measurement. Ann Emerg Med 2010;56(4): 382-388. 3. Ruppel GL, Wilson HA, Gall VK, Hempkens JA. Multi-wavelength pulse oximeter is not suitable for adjusting DLCO measurements. Respir Care ...

متن کامل

Dynamic hyperinflation, intrinsic positive end-expiratory pressure, and respiratory rate.

In reviewing the article “Methemoglobinemia: Sudden Dyspnea and Oxygen Desaturation After Esophagoduodenoscopy,” in the August 2004 issue of RESPIRATORY CARE,1 I found the article suggested that, during the esophagoduodenoscopy procedure the patient’s blood oxygen saturation (measured via pulse oximetry) began to drop rapidly, and a saturation of 54% registered on the pulse oximeter while the p...

متن کامل

Methemoglobinemia and Pulse Oximetry

In reviewing the article “Methemoglobinemia: Sudden Dyspnea and Oxygen Desaturation After Esophagoduodenoscopy,” in the August 2004 issue of RESPIRATORY CARE,1 I found the article suggested that, during the esophagoduodenoscopy procedure the patient’s blood oxygen saturation (measured via pulse oximetry) began to drop rapidly, and a saturation of 54% registered on the pulse oximeter while the p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory physiology & neurobiology

دوره 182 2-3  شماره 

صفحات  -

تاریخ انتشار 2012