Diagnosis of ventricular septal defect by pulsed Doppler echocardiography. Sensitivity, specificity and limitations.

نویسندگان

  • J G Stevenson
  • I Kawabori
  • T Dooley
  • W G Guntheroth
چکیده

The M-mode echocardiographic findings of ventricular septal defect (VSD) are nonspecific. A specific pulsed Doppler echocardiographic (PDE) diagnosis of VSD can be made by following the turbulent VSD jet through the septum. To assess the sensitivity, specificity and limitations of PDE diagnosis of VSD, 105 children undergoing cardiac catheterization were examined by PDE. These children had a variety of cardiac defects, and a PDE diagnosis of VSD was made in 46/51 (90%) who had VSD proven at catheterization. There was one false positive PDE diagnosis of VSD, for a specificity of 98%. Factors influencing the ability to diagnose VSD by PDE include the location of the defect, level of pulmonary vascular resistance and direction of blood flow through the VSD. The presence of additional defects did not interfere with PDE diagnosis of VSD. The PDE detection of additional defects may identify situations where M-mode echocardiographic estimation of dimensions may not be indicative of the size of VSD shunt.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DIAGNOSTIC METHODS CONGENITAL HEART DISEASE Color Doppler detection of multiple ventricular septal defects

Combined two-dimensional and Doppler echocardiography has a high sensitivity and specificity for detection of isolated perimembranous ventricular septal defects. However, muscular or multiple ventricular septal defects may be difficult to diagnose with noninvasive methods, particularly in older children, necessitating angiography for accurate diagnosis. Detection of single and multiple ventricu...

متن کامل

Pulsed Doppler Echocardiography in the Diagnosis of Ventricular Septal Defect and Patent Ductus Arteriosus

some limitations and it is unable to detect small abnormalities beyond the imaging resolution of the apparatus. Ventricular septal defects (VSDs) can only be detected if they are sufficiently large or are associated with certain anatomical malformation (Magherini et al., 1983). Accurate demonstration of a patent ductus arteriosus (PDA) is limited due to echo dropout which makes visualisation of...

متن کامل

Pulsed Doppler echocardiography for diagnosis of ventricular septal defects.

In order to assess the performance of pulsed Doppler echocardiography and to examine the factors affecting its reliability for the diagnosis of ventricular septal defects, 51 patients, in whom angiographic studies had recently been performed, were investigated before and after operation by this technique. The diagnosis was correct in all cases with left-to-right shunt, when the defect was locat...

متن کامل

Sensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects.

Twenty nine patients (aged from three months to 37 years) with confirmed or suspected ventricular septal defects were studied separately by three examiners who used colour flow mapping and imaging, or continuous wave Doppler and imaging, or a combined reference examination. Colour flow mapping identified 19 of the 25 patients with a ventricular septal defect, continuous wave Doppler echocardiog...

متن کامل

Color Doppler detection of multiple ventricular septal defects.

Combined two-dimensional and Doppler echocardiography has a high sensitivity and specificity for detection of isolated perimembranous ventricular septal defects. However, muscular or multiple ventricular septal defects may be difficult to diagnose with noninvasive methods, particularly in older children, necessitating angiography for accurate diagnosis. Detection of single and multiple ventricu...

متن کامل