Measurement of cardiac output in small laboratory animals using recordings of blood conductivity.

نویسنده

  • Johannes Vogel
چکیده

No method exists which enables easy, frequent, and, at the same time, reliable cardiac output (CO) measurements in mice. To validate a simple indicator-dilution method suitable for frequent measurements of CO in small laboratory animals, a 5% glucose solution was injected as a bolus into femoral veins of mice and rats. The corresponding blood conductivity was measured continuously between an intra-aortic and a rectal electrode. The resulting conductivity-dilution curves were used to calculate CO in mice during hypervolemia and hypovolemia and in conscious as well as halothane-anesthetized mice and rats. In rats, conductivity-dilution curves and time courses of plasma glucose concentration were recorded simultaneously. Compared with CO in awake animals, CO in both species was slightly, but not significantly, reduced during halothane anesthesia. CO was significantly and gradually reduced in hypovolemic mice (up to 58 ml blood/kg body wt), whereas hypervolemia (23 ml saline/kg body wt) had no significant effect. Simultaneous recordings of conductivity-dilution curves and time courses of plasma glucose concentration yielded corresponding values of CO ( P < 0.001). Measurement of blood conductivity appears to be a reliable, simple, and convenient method for quantification of CO in small animals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Measurement of the cardiac output in dogs by a conductivity method after single intravenous injections of autogenous plasma.

Equations are developed for the estimation of cardiac output from hematocrit dilution, using the continuously recorded conductivity of whole blood drawn from an artery through a conductivity cell, after a single intravenous injection of autogenous plasma. The equipment used is described, the results are compared with those of simultaneously performed measurements of dye dilution and the advanta...

متن کامل

Measurement Of Scatter Factors For Small Photon Fields Using Gaf chromic EBT2 Film

Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...

متن کامل

Fluorescence dilution technique for measurement of cardiac output and circulating blood volume in healthy human subjects.

BACKGROUND The authors previously validated in an animal model a new indicator dilution technique for measuring cardiac output and circulating blood volume by recording transcutaneously the fluorescence of circulating indocyanine green with an optical probe placed on the skin surface. The current study compared fluorescence dilution recordings recorded from several locations on the human face i...

متن کامل

Measurement of stereotactic beam data of 9 MV X-rays using diode detector

Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The American journal of physiology

دوره 273 5 Pt 2  شماره 

صفحات  -

تاریخ انتشار 1997