OBJECTIVE To reduce the radiation dose, reduced time CT perfusion (CTp) acquisitions are tested to measure permeability surface (PS) with a deconvolution method. METHODS AND MATERIALS PS was calculated with repeated measurements (n = 305) while truncating the time density curve (TDC) at different time values in 14 CTp studies using CTp 4D software (GE Healthcare, Milwaukee, WI, US). The median acquisition time of CTp studies was 59.35 sec (range 49-92 seconds). To verify the accuracy of the deconvolution algorithm, a variation of the truncated PS within the error measurements was searched, that is, within 3 standard deviations from the mean nominal error provided by the software. The test was also performed for all the remaining CTp parameters measured. RESULTS PS maximum variability happened within 25 seconds. The PS became constant after 40 seconds for the majority of the active tumors (10/11), while for necrotic tissues it was consistent within 1% after 50 seconds. A consistent result lasted for all the observed CTp parameters, as expected from their analytical dependance. CONCLUSION 40-second acquisition time could be an optimal compromise to obtain an accurate measurement of the PS and a reasonable dose exposure with a deconvolution method.
منابع مشابه
Perfusion-CT monitoring of cryo-ablated renal cells tumors
BACKGROUND No single and thoroughly validated imaging method in monitoring of cryoablated renal cell carcinoma (RCC) is available. The purpose of our study was to determine the feasibility of dynamic contrast-enhanced perfusion CT (pCT) in evaluating the hemodynamic response of RCC. METHODS 15 patients (14 male, 1 female; age range, 43-81 years; mean age, 62 years) with cryoablated RCC via a ...
متن کاملGlioma Angiogenesis and Perfusion Imaging: Understanding the Relationship between Tumor Blood Volume and Leakiness with Increasing Glioma Grade.
BACKGROUND AND PURPOSE The purpose of this study was to investigate imaging correlates to the changes occurring during angiogenesis in gliomas. This was accomplished through in vivo assessment of vascular parameters (relative CBV and permeability surface-area product) and their changing relationship with increasing glioma grade. MATERIALS AND METHODS Seventy-six patients with gliomas underwen...
متن کاملComparison of blood flow models and acquisitions for quantitative myocardial perfusion estimation from dynamic CT.
Myocardial blood flow (MBF) can be estimated from dynamic contrast enhanced (DCE) cardiac CT acquisitions, leading to quantitative assessment of regional perfusion. The need for low radiation dose and the lack of consensus on MBF estimation methods motivates this study to refine the selection of acquisition protocols and models for CT-derived MBF. DCE cardiac CT acquisitions were simulated for ...
متن کاملPerfusion CT for head and neck tumors: pilot study.
BACKGROUND AND PURPOSE Differentiation of malignant from benign head and neck lesions is often very difficult on imaging studies, especially in patients with treated cancer. We evaluated the feasibility and reproducibility of perfusion CT (CTP) after enhanced head and neck CT and attempted to differentiate benign from malignant processes. METHODS CTP was attempted in 17 patients after head an...
متن کاملCerebral perfusion mapping using a robust and efficient method for deconvolution analysis of dynamic contrast-enhanced images.
Dynamic contrast-enhanced (DCE) imaging using MRI or CT is emerging as a promising tool for diagnostic imaging of cerebral disorders and the monitoring of tumor response to treatment. In this study, we present a robust and efficient deconvolution method based on a linearized model of the impulse residue function, which allows for the mapping of functional cerebral parameters such as cerebral bl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2014 شماره
صفحات -
تاریخ انتشار 2014