Indoor air quality and health problems associated with damp floor coverings.
نویسندگان
چکیده
OBJECTIVES To study the relationship between a high incidence of bronchial asthma among employees working in an office building and an indoor air problem related to the degradation of polyvinyl chloride (PVC) floor coverings in the building. The indoor air measurements and results of renovations are also described. METHODS Employees' symptoms were surveyed by a questionnaire, and the incidence of asthma was calculated from the medical records for 1997-2000. The quality of indoor air was assessed by microbial sampling and by investigation of the building for possible moisture damage. Indoor air was sampled for volatile organic compounds (VOCs) through Tenax adsorbent tubes. In situ volatile emission measurements from the concrete floor were performed via the field and laboratory emission cell (FLEC) method. RESULTS In an office with approximately 150 employees, eight new cases of asthma were found in 4 years. In addition, the workers complained of respiratory, conjunctival and nasal symptoms. Emissions indicating the degradation of plastic floor coverings (e.g. 2-ethyl-1-hexanol, 1-butanol) were found in the indoor air and floor material samples. The plastic floor coverings, adhesives and the levelling layers were carefully removed from 12 rooms. The VOCs had diffused into the underlying concrete slabs. The concrete was warmed to remove the diffused VOCs from these areas. After the repairs the concentrations of the VOCs indicating the degradation of PVC, decreased, as did the prevalence of the employees' symptoms and several asthma patients' need for medication. CONCLUSIONS The workers in the office building complained of several respiratory, conjunctival and dermal symptoms. The incidence of adult-onset asthma was approximately nine-times higher than that among Finns employed in similar work. The most probable single cause of the indoor air problem was the degradation of the plastic floor coverings.
منابع مشابه
Modeling Diffusion-controlled Emissions of Volatile Organic Compounds from Building Materials
The adverse effects of contaminated outdoor air have been recognized and subject to control for many years. More recently environmental engineers and health professionals have become cognizant of the hazards associated with contaminated indoor air. It is now understood that contaminated indoor air negatively impacts human health, worker productivity, and physical property. Volatile organic comp...
متن کاملElements That Contribute to Healthy Building Design
BACKGROUND The elements that contribute to a healthy building are multifactorial and can be discussed from different perspectives. OBJECTIVES WE PRESENT THREE VIEWPOINTS OF DESIGNING A HEALTHY BUILDING: the importance of sustainable development, the role of occupants for ensuring indoor air quality, and ongoing developments related to indoor finishes with low chemical emissions and good funga...
متن کاملHydrophilic Fungi and Ergosterol Associated with Respiratory Illness in a Water-Damaged Building
BACKGROUND Damp building-related respiratory illnesses are an important public health issue. OBJECTIVE We compared three respiratory case groups defined by questionnaire responses [200 respiratory cases, 123 of the respiratory cases who met the epidemiologic asthma definition, and 49 of the epidemiologic asthma cases who had current physician-diagnosed asthma with post-occupancy onset] to a c...
متن کاملEvaluation of air quality in intensive care units and its relationship with sick building syndrome in nurses
Introduction: Indoor air quality can lead to health problems such as Sick Building Syndrome among nurses who spend many hours in intensive care units.The aim of this study was to determine the relationship between Sick Building Syndrome in nurses and indoor air quality of intensive care units in educational hospitals in Rasht. Materials and Methods: This cross-sectional analytical study was pe...
متن کاملبررسی آلاینده های شاخص هوای داخل و خارج منازل مسکونی شهری
Background and purpose: Indoor air pollution in developing countries is considered as one of the main problems in healthcare. This study aimed at investigating the levels of indoor/outdoor air pollutants in Khorramabad during autumn and winter 2012. Materials and methods: In a cross-sectional study, nine gas concentrations and particulate pollutants were measured using air pollution measuring ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International archives of occupational and environmental health
دوره 77 3 شماره
صفحات -
تاریخ انتشار 2004