Assessing the Oldness and Capacity of Radiography and Ultrasound Equipments in Tehran University of Medical Sciences

نویسندگان

  • Payman Salamati
  • Hossein Ghanaati
  • Shahram Ghasemzadeh
  • Amir Hossein Jalali
چکیده

BACKGROUND Maintenance of imaging equipment is a very important part of the management of all medical imaging centers. OBJECTIVES To assess the oldness and capacity of radiography and ultrasound equipment in Tehran University of Medical Sciences. MATERIALS AND METHODS The study was performed in 16 hospitals, 4 faculties and three healthcare centers of Tehran University of Medical Sciences. We evaluated all the X-ray equipment (including the simple plain and dental, panorex, mammography, fluoroscopy and C-arm X-Ray devices) and also simple and Doppler ultrasound machines in terms of the type and usage of the device, production year, quantity of utilization, location, brand and current condition. RESULTS Among fixed X-ray systems, 15 were currently in use, two were junk, two were damaged, and one was not utilized. The mean (SD) of the usage of these was 2151 (2230) cliché/month, and the mean (SD) of the oldness was 16.9 (13.6) years. The oldness of radiography equipment in our study was more than 20 years in 16, between 11 and 20 in 46, and less than 10 years in 76 devices. The mean (SD) usage (patients/month) of simple and color Doppler devices were 234.1 (365.2) and 597.5 (505.3), respectively. The oldness of ultrasonography equipment in our study was more than 11 years in 12 and less than 10 years in 55 devices. We found that 22 (15.9%) of the radiography systems and two (3%) of the ultrasonography systems had been used for more than 20 years. CONCLUSION Radiology equipment in Tehran University of Medical Sciences have potential capacity, but they need repair, and better maintenance and management and application of standards for the imaging system needs organized supervisory mechanisms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality Control of Radiography Equipments in Golestan Province of IRAN

Introduction The main goal of this study was to perform quality control test on all radiography units operating in Golestan province of IRAN. Materials and Methods Forty-four X-ray units were examined based on general accepted programs for quality control. Eight parameters including kVp accuracy, kVp reproducibility, mA-time reciprocity, exposure linearity, exposure reproducibility, timer accur...

متن کامل

Comparative Evaluation of Ultrasound Against Conventional Radiography in Patients With Nasal Bone Fractures

Introduction: Nasal bone fractures are one of the most common problems in patients who are referred to otolaryngology centers. We aimed to evaluate physical examination, sonography and conventional lateral nasal bone radiography in patients with nasal bone trauma and its relation to intra-operative findings. Methods: This prospective study was performed on 200...

متن کامل

Evaluation of Diagnostic Value of Clinical Ultrasonography Compared to Radiography in the Diagnosis of Metacarpal Fractures in the Emergency

Background and Objectives: Metacarpal and finger fractures are the most common upper organ injuries in the emergency. The hand is one of the most important and effective part in this organ. Diagnosis and treatment for these organs are crucial until complete recovery. The aim of this study was to evaluate the diagnostic value of ultrasonography compared to radiography in the diagnosis of metacar...

متن کامل

P-107: Can Combination of Hysterosalpingography and Ultrasound Replace Hysteroscopy in Diagnosis of Uterine Malformations in Infertile Women?

Background Müllerian anomalies are associated with infertility. Hysteroscopy as the gold standard of evaluating Müllerian anomalies is an invasive, expensive and risky procedure which requires enough experience. Transvaginal sonography (TVS) and hysterosalpingography (HSG) are less invasive procedures, but their accuracy is unknown. The aim of this study was to compare the accuracy of combinati...

متن کامل

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

1Medical Physics and Biomedical Engineering Department, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran 2Nuclear Sciences Research School, Radiation Applications Research School, Tehran, Iran 3National Radiation Protection Department, Iranian Nuclear Regulatory Authority, Teheran Iran 4Nuclear Sciences Research School, Nuclear Sciences and Technology Research Institute, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2013