Femoral artery inflow in relation to external and total work rate at different knee extensor contraction rates.

نویسندگان

  • Takuya Osada
  • Göran Rådegran
چکیده

Whether limb blood flow is directly regulated to match the work rate, independent of the rate of contraction, remains elusive. This study therefore investigated the relationship between femoral arterial blood flow (FABF; Doppler ultrasound) and "external" (applied load) as well as "total" [external + "internal" (potential and kinetic energy changes of the moving lower leg)] work rate, during steady-state one-legged, dynamic, knee extensor exercise (1L-KEE) in the sitting position at different contraction rates. Ten subjects performed 1L-KEE at 30, 60, and 90 contractions/min (cpm) 1) at constant resistive loads of 0.2 and 0.5 kg inducing incremental external work rates (study I) and 2) at different relative resistive loads inducing constant external work rates of 9 and 18 W (study II). Moreover, 3) six subjects performed 1L-KEE at 60 and 100 cpm at incremental total work rates of 40, 50, 60, and 70 W (study III). In study I, FABF increased (P < 0.001) with increasing contraction frequency and external work rate, for each resistive load. In study II, FABF increased (P < 0.001) with increasing contraction frequency for each constant external work rate. Of major importance in study III, however, was that FABF, although increasing linearly with the total work rate, was not different (P = not significant) between contraction rates, at the total work rates of 40, 50, 60, and 70 W, respectively. Furthermore, FABF correlated linearly and positively with both the external and total work rate for each contraction frequency. In conclusion, the findings support the concept that leg blood flow during 1L-KEE in a normal knee extensor ergometer is matched directly in relation to the total work rate and metabolic activity, irrespective of the contraction frequency. The rate of contraction seems erroneously to influence the results only when it is related to the external work rate without taking into account the internal work component.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans.

Ultrasound Doppler has been used to measure arterial inflow to a human limb during intermittent static contractions. The technique, however, has neither been thoroughly validated nor used during dynamic exercise. In this study, the inherent problems of the technique have been addressed, and the accuracy was improved by storing the velocity tracings continuously and calculating the flow in relat...

متن کامل

The Comparison of Isokinetic Parameters of Hip and Knee Joint Muscles in Professional Soccer Players with Athletic Groin Pain and Healthy One: Implications for Sports Injuries Prevention

Aims and background: This study aimed to investigate the comparison of isokinetic parameters of hip and knee joint muscles in professional soccer players with athletic groin pain (AGP) and healthy ones. Material and Methods: 32 soccer players (control group (n=16) and AGP group (n=16)) who take part in the first and second division league participated in this study. The isokinetic dynamometer ...

متن کامل

The Effect of Kinesio Taping on Electromyography Activity and Co-Contraction of knee Muscles in People with Patellofemoral Pain Syndrome during climbing and descending stairs

Introduction and aim: Ascending and descending stairs are one of the challenging activities for people with patellofemoral pain syndrome. Kinesiotype is one of the rehabilitation methods to improve the symptoms of patellofemoral pain syndrome.  This study aimed to evaluate the effect of kinesiotype on electromyographic activity and co-contraction of knee muscles in patients with patellofemoral ...

متن کامل

Muscle contraction-blood flow interactions during upright knee extension exercise in humans.

To test for evidence of a muscle pump effect during steady-state upright submaximal knee extension exercise, seven male subjects performed seven discontinuous, incremental exercise stages (3 min/stage) at 40 contractions/min, at work rates ranging to 60-75% peak aerobic work rate. Cardiac cycle-averaged muscle blood flow (MBF) responses and contraction-averaged blood flow responses were calcula...

متن کامل

Radiologic Assessment of Distal Femur Cutting Angle in Varus Knee Candidates for Total Knee Arthroplasty

Background: In a total knee arthroplasty surgery the goal is to produce 90 degree angle between the knee articular lobe and the mechanical femoral line. Most orthopedic surgeons usually utilize a 5 to 7 degree for distal femoral cutting angle. In this study we will aim at clearing this question, that whether the” five-seven degree” distal femoral cutting angle supposed to be an equable spectrum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 92 3  شماره 

صفحات  -

تاریخ انتشار 2002