Sensory Guided Surgical Micro-drill
نویسنده
چکیده
In this paper a surgical robotic device is described that is able to discriminate tissue interfaces and other controlling parameters ahead of the drill tip. The advantage in surgery is that tissues at interfaces can be preserved. The smart tool detects ahead of the tool point and is able to control interaction with respect to the flexing tissue to avoid penetration or to control the extent of protrusion with respect to the position of the tissue. For surgical procedures where precision is required the tool offers significant benefit. To interpret drilling conditions, and conditions leading up to breakthrough at a tissue interface, a sensing scheme is used that discriminates between the variety of conditions posed in the drilling environment. The result is a fully autonomous system able to respond to tissue type, behaviour and deflection in real-time. The system is also robust in terms of disturbances encountered in the operating theatre. The device is pragmatic. It is intuitive to use, efficient to set up and uses standard drill bits. The micro-drill has been used to prepare cochleostomies in theatre and was used to remove bone tissue leaving the endosteal membrane intact. This has enabled preservation of sterility and the drilling debris to be removed prior to insertion of the electrode. It is expected that this technique will promote preservation of hearing and reduce the possibility of complications. The paper describes the device (including simulated drill progress and hardware setup) and the stages leading up to use in theatre.
منابع مشابه
In-vitro evaluation of the tolerance of surgical instruments in templates for computer-assisted guided implantology produced by 3-D printing.
OBJECTIVE The aim of this in-vitro study was to compare the tolerance of surgical instruments in surgical guides produced by 3-D printing, without metal sleeves to a surgical guide with conventional metal sleeves from two different manufacturers. MATERIALS AND METHODS Lateral movements of drill tips caused by tolerance between the sleeve and drill key and between the drill key and the drill w...
متن کاملDesign of a multifiber light delivery system for photoacoustic-guided surgery.
This work explores light delivery optimization for photoacoustic-guided minimally invasive surgeries, such as the endonasal transsphenoidal approach. Monte Carlo simulations were employed to study three-dimensional light propagation in tissue, comprising one or two 4-mm diameter arteries located 3 mm below bone, an absorbing metallic drill contacting the bone surface, and a single light source ...
متن کاملComparison of heat generation between internally guided (cannulated) single drill and traditional sequential drilling with and without a drill guide for dental implants.
PURPOSE To determine whether a wire-guided single drill protocol could be utilized without causing an increase in bone temperature beyond those seen with the traditional techniques of sequential drilling with and without a drill guide. MATERIALS AND METHODS A bovine femoral bone model was used with thermocouples and infrared temperature measurements to record thermal increase of the bone and ...
متن کاملEffect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs.
Background/Aim During drilling implant sites, mechanical energy is converted into thermal one resulting in transient rise in temperature of surrounding bone. The temperature of 47°C exeeding one minute impairs osseointegration, compromises mechanical properties of the local bone and could cause early implant failure. This in vitro study aimed to assess the effect of surgical drill guide and tem...
متن کاملA novel drill design for photoacoustic guided surgeries
Fluoroscopy is currently the standard approach for image guidance of surgical drilling procedures. In addition to the harmful radiation dose to the patient and surgeon, fluoroscopy fails to visualize critical structures such as blood vessels and nerves within the drill path. Photoacoustic imaging is a well-suited imaging method to visualize these structures and it does not require harmful ioniz...
متن کامل