Evaluation of Dose Distribution in Intensity Modulated Radiosurgery for Lung Cancer under Condition of Respiratory Motion

نویسندگان

  • Mee Sun Yoon
  • Jae-Uk Jeong
  • Taek-Keun Nam
  • Sung-Ja Ahn
  • Woong-Ki Chung
  • Ju-Young Song
چکیده

The dose of a real tumor target volume and surrounding organs at risk (OARs) under the effect of respiratory motion was calculated for a lung tumor plan, based on the target volume covering the whole tumor motion range for intensity modulated radiosurgery (IMRS). Two types of IMRS plans based on simulated respiratory motion were designed using humanoid and dynamic phantoms. Delivery quality assurance (DQA) was performed using ArcCHECK and MapCHECK2 for several moving conditions of the tumor and the real dose inside the humanoid phantom was evaluated using the 3DVH program. This evaluated dose in the tumor target and OAR using the 3DVH program was higher than the calculated dose in the plan, and a greater difference was seen for the RapidArc treatment than for the standard intensity modulated radiation therapy (IMRT) with fixed gantry angle beams. The results of this study show that for IMRS plans based on target volume, including the whole tumor motion range, tighter constraints of the OAR should be considered in the optimization process. The method devised in this study can be applied effectively to analyze the dose distribution in the real volume of tumor target and OARs in IMRT plans targeting the whole tumor motion range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.

Introduction:   The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer.   Materials and Methods:   Two CT scan was performred for each pati...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Intensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields

Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...

متن کامل

The influence of respiratory motion on dose distribution of 3D-CRT and IMRT- A simulation study

Background: 3DCRT (three-dimensional conformal radiotherapy) and IMRT (intensity-modulated radiotherapy) has provided us with tools to delineate the radiation dose distribution of tumor targets. However, the precision of radiation can be compromised by respiratory motion, which usually limits the geometric and dosimetric accuracy of radiotherapy. The purpose of this study is to evaluate the imp...

متن کامل

Evaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms

Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016