Influence of assessment site in measuring transcutaneous bilirubin

نویسندگان

  • Cristiane Maria da Conceição
  • Maria Fernanda Pellegrino da Silva Dornaus
  • Maria Aparecida Portella
  • Alice D'Agostini Deutsch
  • Celso Moura Rebello
چکیده

OBJECTIVE To investigate the influence of the site of measurement of transcutaneous bilirubin (forehead or sternum) in reproducibility of results as compared to plasma bilirubin. METHODS A cohort study including 58 term newborns with no hemolytic disease. Transcutaneous measurements were performed on the forehead (halfway between the headline and the glabella, from the left toward the right side, making consecutive determinations, one-centimeter apart) and the sternum (five measurements, from the suprasternal notch to the xiphoid process with consecutive determinations, one-centimeter apart) using Bilicheck® (SpectRx Inc, Norcross, Georgia, USA). The correlation and agreement between both methods and plasma bilirubin were calculated. RESULTS There was a strong linear correlation between both determinations of serum bilirubin at the forehead and sternum (r=0.704; p<0.01 and r=0.653; p<0.01, respectively). There was correspondence of the mean values of transcutaneous bilirubin measured on the sternum (9.9 ± 2.2mg/dL) compared to plasma levels (10.2 ± 1.7 mg/dL), but both differ from the values measured on the forehead (8.6 ± 2 .0mg/dL), p<0.05. CONCLUSION In newborn term infants with no hemolytic disease, measuring of transcutaneous bilirubin on the sternum had higher accuracy as compared to serum bilirubin measurement on the forehead.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the first day transcutaneous bilirubin (TcB) level as a predictor of hyperbilirubinemia in healthy term neonates

Background: The readmission rate for neonatal jaundice has been increased in recent years. This has been attributed to shorter length of postpartum hospital stays without comprehensive follow-up. The purpose of this study was to determine the diagnostic value of pre-discharge transcutaneous bilirubin (TcB) levels for prediction of subsequent hyperbilirubinemia in healthy term neonates. Metho...

متن کامل

A Comparison between Transcutaneous Bilirubin (TcB) and Total Serum Bilirubin (TSB) Measurements in Term Neonates

Background: Transcutaneous bilirubinometry (TCB) is a simple method for estimating bilirubin levels in neonates. This method is noninvasive, quick, and painless. We aimed to compare serum and cutaneous bilirubin measurements in term neonates.Method: In this descriptive cross-sectional study, 200 neonates with icter with birth weights of at least 2500 grams were studied. TCB was measured using a...

متن کامل

بررسی ارزش تشخیصی اندازه گیری پوستی بیلی روبین در نوزادان بیمار

Background and purpose: Neonatal icter is one of the most prevalent diseases in neonatal period and may lead to serious important complications such as kern icterus. For appropriate therapeutic approach to these patients, there is need of blood sampling and in some cases, repeated blood sampling, in order to measure bilirubin which causes certain complications such as infection, anemia, pain ...

متن کامل

مقایسه میانگین بیلی روبین اندازه گیری شده از طریق بیلی روبینومتر با میانگین بیلی روبین سرم در نوزادان زرد

Introduction: Hyperbilirubinemia is a common benign problem in neonates. Nonetheless, if untreated, severe hyperbilirubinemia is potentially neurotoxic. The standard method for diagnosis of hyperbilirubinemia is determination of serum bilirubin levels in the laboratory that requires a blood sample which is both painful and stressful for neonates and entails cost and time. The objective of thi...

متن کامل

Application of transcutaneous bilirubinometry for screening of neonates with significant hyperbilirubinemia in the city of Kerman

In order to screen for neonatal significant hyperbilirubinemia,a propective cross sectional study was carried out on 343 full-term neonates taken to investigator in Kerman between October 1995 and july 1996.there was a linear correlation between serum bilirubin and transcutaneous bilirubinometri (r=0.85,standard error=0.004).sensitivity and specificity of this method were 95% and 84% respective...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2014