Analysis of postnatal eye development in the mouse with high-resolution small animal magnetic resonance imaging.
نویسندگان
چکیده
PURPOSE Studies of myopia in mice have been complicated by the difficulty in obtaining accurate measurements of small changes observed in the growing mouse eye in vivo and the lack of data on refractive eye development. The purpose of this study was to carry out an in vivo high-resolution analysis of mouse eye growth and refractive development. METHODS High-resolution small animal magnetic resonance imaging and high-resolution infrared photorefraction were used to analyze refractive development in postnatal day (P)21 to P89 C57BL/6J mice. RESULTS The growth of the mouse eye decelerated after P40. The eye maintained a slightly prolate shape during growth. The anterior chamber growth exhibited a similar pattern, whereas the corneal radius of curvature (CRC) increased linearly. The growth rate of the lens remained constant until P89. The lens "overgrew" the eye at P40, resulting in a decline in vitreous chamber depth. Mice showed myopic refractive errors at a younger age (-13.2 +/- 2.0 D; mean +/- SD, P21). The refractive errors stabilized around emmetropic values by P32 and remained emmetropic until P40. Mice became progressively hyperopic with age (+1.2 +/- 1.7 D, P67; +3.6 +/- 2.3 D, P89). CONCLUSIONS Development of ocular components in the mouse is similar to that of the tree shrew but different from that of higher primates and humans. Primary differences can be attributed to the age-related changes of the crystalline lens and CRC. In spite of these differences, mice appear to be able to achieve and maintain emmetropic refractive status at P32 to P40.
منابع مشابه
Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملThe modeling of induced current density in eyes from static magnetic fields produce by MR scanner
Introduction: Staff and patient Movement in static magnetic field MRI scanner induces current density in the human tissues, so cause biologic effects in people. The aim of this study was the Modelling of current density induced by moving individual with different velocities in static magnetic field of magnetic resonance imaging. Materials and Methods: current ...
متن کاملMagnetic resonance imaging of feline eye
The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...
متن کاملDesigning and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance
Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...
متن کاملAn investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter
Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 51 1 شماره
صفحات -
تاریخ انتشار 2010