Mid-term results of aortic root replacement using a self-assembled biological composite graft.

نویسندگان

  • Katharina Meszaros
  • Sophia Liniger
  • Martin Czerny
  • Olaf Stanger
  • David Reineke
  • Lars Englberger
  • Thierry P Carrel
چکیده

OBJECTIVES To report the mid-term results of aortic root replacement using a self-assembled biological composite graft, consisting of a vascular tube graft and a stented tissue valve. METHODS Between January 2005 and December 2011, 201 consecutive patients [median age 66 (interquartile range, IQR, 55-77) years, 31 female patients (15.4%), median logistic EuroSCORE 10 (IQR 6.8-23.2)] underwent aortic root replacement using a stented tissue valve for the following indications: annulo-aortic ectasia or ascending aortic aneurysm with aortic valve disease in 162 (76.8%) patients, active infective endocarditis in 18 (9.0%) and acute aortic dissection Stanford type A in 21 (10.4%). All patients underwent clinical and echocardiographic follow-up. We analysed survival and valve-related events. RESULTS The overall in-hospital mortality rate was 4.5%. One- and 5-year cardiac-related mortality rates were 3 and 6%, and overall survival was 95 ± 1.5 and 75 ± 3.6%, respectively. The rate of freedom from structural valve failure was 99% and 97 ± 0.4% at the 1- and 5-year follow-up, respectively. The incidence rates of prosthetic valve endocarditis were 3 and 4%, respectively. During a median follow-up of 28 (IQR 14-51) months, only 2 (1%) patients required valve-related redo surgery due to prosthetic valvular endocarditis and none suffered from thromboembolic events. One percent of patients showed structural valve deterioration without any clinical symptoms; none of the patients suffered greater than mild aortic regurgitation. CONCLUSIONS Aortic root replacement using a self-assembled biological composite graft is an interesting option. Haemodynamic results are excellent, with freedom from structured valve failure. Need for reoperation is extremely low, but long-term results are necessary to prove the durability of this concept.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modified bio-Bentall procedure: 10-year experience.

OBJECTIVE Biological aortic valve conduits are rarely used because of the concern that possible structural valve deterioration would require complete conduit replacement in a technically demanding operation. The aim of the study was to evaluate the 10-year experience with complete aortic-root replacement using a modified composite graft in which biological valve prosthesis was located inside th...

متن کامل

Improved outcome with composite graft versus homograft root replacement for children with aortic root aneurysms.

OBJECTIVE Review of surgical repair of aortic root aneurysms using composite graft or homograft in children. METHODS A consecutive series of 34 children (mean age 10.8+/-5.4 years) who underwent elective aortic root replacement using composite graft or homograft from 1987 to 2003 (mean follow-up 5.7+/-3.7 years). RESULTS Preoperatively, the aortic annulus and aortic root average z-scores we...

متن کامل

Pii: S1010-7940(01)00799-0

Objective: The composite mechanical valve conduit has been most commonly used for patients who require combined aortic valve, root, and ascending aorta replacement, but is limited, especially in the elderly, because of the need for long-term anticoagulation. We report the ®rst consecutive series of patients in whom a composite stentless valve with graft extension, which does not require long-te...

متن کامل

Aortic root replacement in children: a word of caution about valve-sparing procedures.

OBJECTIVE Evaluate the results of various surgical procedures used for aortic root replacement in children with aortic root aneurysm. METHODS Between 1986 and 2007, 23 children (less than 16 years of age, mean age: 8.1+/-5.1 years) underwent elective aortic root replacement for aortic root aneurysm (with associated aortic insufficiency in 10 patients). All had connective tissue defect syndrom...

متن کامل

Valve-sparing aortic root replacement in patients after a previous operation for acute type A aortic dissection.

T he list of long-term complications after surgical intervention for acute type A aortic dissection includes recurrent dissection, aneurysm formation, and aortic valve regurgitation. Ten years after the initial operation for acute type A dissection, the reoperation rate for these kinds of long-term complications is 13% to 30% in the literature.1 The diseased aortic root in these patients is com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2014