Biological augmentation of rotator cuff repair using bFGF-loaded electrospun poly(lactide-co-glycolide) fibrous membranes

نویسندگان

  • Song Zhao
  • Jingwen Zhao
  • Shikui Dong
  • Xiaoqiao Huangfu
  • Bin Li
  • Huilin Yang
  • Jinzhong Zhao
  • Wenguo Cui
چکیده

Clinically, rotator cuff tear (RCT) is among the most common shoulder pathologies. Despite significant advances in surgical techniques, the re-tear rate after rotator cuff (RC) repair remains high. Insufficient healing capacity is likely the main factor for reconstruction failure. This study reports on a basic fibroblast growth factor (bFGF)-loaded electrospun poly(lactide-co-glycolide) (PLGA) fibrous membrane for repairing RCT. Implantable biodegradable bFGF-PLGA fibrous membranes were successfully fabricated using emulsion electrospinning technology and then characterized and evaluated with in vitro and in vivo cell proliferation assays and repairs of rat chronic RCTs. Emulsion electrospinning fabricated ultrafine fibers with a core-sheath structure which secured the bioactivity of bFGF in a sustained manner for 3 weeks. Histological observations showed that electrospun fibrous membranes have excellent biocompatibility and biodegradability. At 2, 4, and 8 weeks after in vivo RCT repair surgery, electrospun fibrous membranes significantly increased the area of glycosaminoglycan staining at the tendon-bone interface compared with the control group, and bFGF-PLGA significantly improved collagen organization, as measured by birefringence under polarized light at the healing enthesis compared with the control and PLGA groups. Biomechanical testing showed that the electrospun fibrous membrane groups had a greater ultimate load-to-failure and stiffness than the control group at 4 and 8 weeks. The bFGF-PLGA membranes had the highest ultimate load-to-failure, stiffness, and stress of the healing enthesis, and their superiority compared to PLGA alone was significant. These results demonstrated that electrospun fibrous membranes aid in cell attachment and proliferation, as well as accelerating tendon-bone remodeling, and bFGF-loaded PLGA fibrous membranes have a more pronounced effect on tendon-bone healing. Therefore, augmentation using bFGF-PLGA electrospun fibrous membranes is a promising treatment for RCT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel nanofiber-based scaffold for rotator cuff repair and augmentation.

The debilitating effects of rotator cuff tears and the high incidence of failure associated with current grafts underscore the clinical demand for functional solutions for tendon repair and augmentation. To address this challenge, we have designed a poly(lactide-co-glycolide) (PLGA) nanofiber-based scaffold for rotator cuff tendon tissue engineering. In addition to scaffold design and character...

متن کامل

Silver Nanoparticles/Ibuprofen-Loaded Poly(l-lactide) Fibrous Membrane: Anti-Infection and Anti-Adhesion Effects

Infection caused by bacteria is one of the crucial risk factors for tendon adhesion formation. Silver nanoparticles (AgNP)-loaded physical barriers were reported to be effective in anti-infection and anti-adhesion. However, high silver load may lead to kidney and liver damages. This study was designed for Ibuprofen (IBU)-loaded poly(L-lactide) (PLLA) electrospun fibrous membranes containing a l...

متن کامل

Regeneration of rotator cuff tear using electrospun poly(d,l-Lactide-Co-Glycolide) scaffolds in a rabbit model.

PURPOSE The purpose of this study was to evaluate an application of poly(d,l-lactide-co-glycolide) (PLG) scaffold created by electrospinning in a rabbit rotator cuff defect model. METHODS Forty-two Japanese white rabbits were used in this study. Defects of the infraspinatus tendon were created, and the PLG scaffolds were implanted. Contralateral infraspinatus tendons were reattached without c...

متن کامل

In Vivo Evaluation of a Bi-Phasic Nanofiber-Based Scaffold for Integrative Rotator Cuff Repair

INTRODUCTION: Over 300,000 rotator cuff repair surgeries are performed annually[1]. Injuries to the rotator cuff often occur at the tendon-to-bone insertion[2], thus tendon integration is critical for long term stability and functionality of clinical repair. The native tendon-tobone junction consists of a continuous transition from the tendon proper to non-calcified and calcified fibrocartilage...

متن کامل

Fabrication of electrospun poly(d,l lactide-co-glycolide)80/20 scaffolds loaded with diclofenac sodium for tissue engineering

BACKGROUND Adaptation of nanotechnology into materials science has also advanced tissue engineering research. Tissues are basically composed of nanoscale structures hence making nanofibrous materials closely resemble natural fibers. Adding a drug release function to such material may further advance their use in tissue repair. METHODS In the current study, bioabsorbable poly(D,L lactide-co-gl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014