STATEMENT OF PROBLEM For patients with limited interocclusal space, standard height implant abutments may not be usable. Shorter abutments may be desirable. PURPOSE The purpose of this study was to determine the effect of the height of titanium abutments on the tensile strength required to dislodge zirconia copings. MATERIAL AND METHODS Two experimental groups of abutments were prepared: (1) 4.3-mm platform width implant abutment with a 6.5-mm height (control), and (2) a 4.3-mm platform width implant abutment with a 5.5-mm height (shorter). Each abutment had 5 zirconia copings (custom designed) fabricated through a 3-dimensional computer-assisted design (3-D CAD) process by scanning an identical wax pattern. The zirconia copings were designed to have a 6-mm projection above the titanium abutment to accommodate a 2-mm hole. A wire was inserted through this hole to attach the zirconia coping to a universal testing machine. Each abutment was placed onto an implant embedded in a brass base designed to fit onto the universal testing machine. The zirconia copings were cemented onto the abutments with a provisional luting agent (Improv), and a tensile force was applied at a crosshead speed of 0.5 mm/min. The removal force was recorded for each specimen. An unpaired t test was used for the statistical analysis (alpha =.05). RESULTS The mean force (SD) necessary to remove the zirconia copings (Newtons) from the 6.5-mm titanium abutment (198.09 (28.83)) was higher (P=.0078) than for the 5.5-mm abutment (124.89 (36.388)). CONCLUSIONS By increasing the height of the abutment 1 mm and maintaining the diameter of the abutment, the resistance to tensile forces increased significantly between the 2 abutment dimensions evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment and comparison of retention of zirconia copings luted with different cements onto zirconia and titanium abutments: An in vitro study

AIM The purpose of this in vitro study was to assess and compare the retention of zirconia copings luted with different luting agents onto zirconia and titanium abutments. MATERIALS AND METHODS Titanium and zirconia abutments were torqued at 35 N/cm onto implant analogs. The samples were divided into two groups: Group A consisted of four titanium abutments and 32 zirconia copings and Group B ...

متن کامل

Abstracts [Bonding Titan_Zirkon] 32012

Two experimental groups of abutments were prepared: (1) 4.3-mm platform width implant abutment with a 6.5-mm height (control), and (2) a 4.3-mm platform width implant abutment with a 5.5-mm height (shorter). Each abutment had 5 zirconia copings (custom designed) fabricated through a 3-dimensional computer-assisted design (3-D CAD) process by scanning an identical wax pattern. The zirconia copin...

متن کامل

Effects of proximal grooves and abutment height on the resistance of resin-cemented crowns in teeth with inadequate resistance: An in vitro study.

BACKGROUND The resistance form is a key factor for a successful crown fabrication. This in vitro study evaluates the effects of proximal grooves and abutment height on the resistance of single cast crowns in molars with inadequate resistance. METHODS Sixty extracted human molars were prepared to possess 20° of total occlusal convergence for single crown fabrication. All of the prepared teeth ...

متن کامل

Fracture Strength of Implant-Supported Ceramic Crowns with Customized Zirconia Abutments: Screw Retained vs. Cement Retained.

PURPOSE To compare the fracture resistance before and after cyclic fatigue assays of ceramic crowns with customized zirconia abutments when screw retained and cemented onto implants. MATERIALS AND METHODS The sample of this study consisted of 40 ceramic crowns with zirconia infrastructure fixed onto external hexagonal implants. The crowns were distributed into two groups (n = 20): Screw-retai...

متن کامل

Fracture resistance and analysis of stress distribution of implant-supported single zirconium ceramic coping combination with abutments made of different materials.

The purpose of this study was to compare the fracture resistance and fracture mode of single implant-zirconium coping combinations using zirconium and titanium abutments and to analyze the stress distribution pattern using three-dimensional finite elements analysis. Twenty implants with titanium and zirconium abutments were randomly divided into two groups (n = 10) and into resin blocks. Zircon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 99 1  شماره 

صفحات  -

تاریخ انتشار 2008