Methods to extract more light from minute scintillation crystals used in an ultra-high resolution positron emission tomography detector
نویسندگان
چکیده
Recently, there has been great interest in developing finely pixellated position-sensitive scintillation detectors for ultra-high-resolution Positron Emission Tomography (PET) systems designed for breast cancer detection, diagnosis, and staging and for imaging small laboratory animals. We are developing a different high-resolution PET detector design that promotes nearly complete scintillation light collection in p1mm wide, >10mm thick lutetium oxyorthosilicate (LSO) crystals. The design requires the use of semiconductor photodetector arrays in novel configurations that significantly improve the light collection aspect ratio for minute crystals. To reduce design complexity and dead area we are investigating the use of 1mm thick sheets of LSO in addition to discrete crystal rods, and the use of position-sensitive avalanche photodiodes (PSAPDs) which require only four readout channels per device, in addition to pixellated APD arrays. Using a 1mm thick scintillation crystal sheet coupled to a finely pixellated APD array results in a pseudo-discrete response to flood irradiation: due to a very narrow light spread function in the thin sheet we observe sharp (o1mm wide) peaks in sensitivity centered at the APD pixel locations in a very linear fashion all the way out to the crystal edge. We measured an energy resolution of 13.7% FWHM at 511 keV for a 1mm LSO crystal coupled to two APD pixels. Using a 1mm thick crystal sheet coupled to a PSAPD the response to flood and edge-on irradiation with a Na point source shows a compressed dynamic range compared to that observed with discrete crystals or direct X-ray irradiation. With a discrete LSO crystal array the flood response is peaked at the crystal location where light is focused onto one spot on the PSAPD. We observed strong pin-cushioning effects in all PSAPD measurements. All LSO–PSAPD configurations studied had high aspect ratio for light collection and achieved energy resolutions p12% FWHM at 511 keV. r 2004 Elsevier B.V. All rights reserved. PACS: 87.59. e; 87.59.Vb; 29.40.Mc
منابع مشابه
Design of a High-Resolution and High-Sensitivity Scintillation Crystal Array for PET With Nearly Complete Light Collection
Spatial resolution improvements in positron emission tomography (PET) can be achieved by developing detector arrays with finer resolution elements. To maintain high sensitivity and image quality, the challenge is to develop a finely pixellated scintillation crystal array with both high detection efficiency and high light collection. High detection efficiency means the crystals must be relativel...
متن کاملA New Photodiode Readout Scheme for High Resolution Scintillation Crystal Arrays
We are exploring the possibility of using PIN photodiodes to readout the scintillation crystals used in Positron Emission Tomography (PET) detector designs. Solid state photodetectors typically have a lower signal to noise ratio than photomultiplier tubes (PMTs). However, they have the advantage of compactness, and, thus, scintillation crystal readout schemes not available to PMTs because of th...
متن کاملInvestigation of a New Readout Scheme for High Resolution Scintillation Crystal Arrays Using Photodi - Nuclear Science, IEEE Transactions on
We are exploring the possibility of using PIN photodiodes to readout the scintillation crystals used in Positron Emission Tomography (PET) detector designs. Semiconductor photodetectors typically have a lower signal to noise ratio than photomultiplier tubes (PMTs). However, they have the advantage of compactness, and, thus, scintillation crystal readout schemes not available to PMTs because of ...
متن کاملInvestigating the temporal resolution limits of scintillation detection from pixellated elements: comparison between experiment and simulation.
This study investigates the physical limitations involved in the extraction of accurate timing information from pixellated scintillation detectors for positron emission tomography (PET). Accurate physical modeling of the scintillation detection process, from scintillation light generation through detection, is devised and performed for varying detector attributes, such as the crystal element le...
متن کاملGrowth of CsI(Tl) crystals doped with Ca and Tm and investigation of its scintillation characteristics
In this work, the growth of CsI(Tl) crystals as gamma detector was performed using vertical Bridgman method with Ca and Tm co-dopants. For evaluation of the growth crystals, X-Ray Diffraction (XRD), photoluminescence and thermoluminescence spectra as well as recorded gamma spectra were employed. In addition, the scintillation properties including energy resolution, scintillation decay time, abs...