Postoperative aqueous outflow in the human eye after glaucoma filtration surgery: biofluidmechanical considerations.
نویسندگان
چکیده
To evaluate the possible postoperative outflow from the anterior chamber of the eye after filtration surgery, a mathematical model based on fluid mechanical principles and clinical data is proposed. Two ophthalmic surgical procedures, non-penetrating deep sclerectomy and trabeculectomy, were analyzed. Based on mathematical modeling, the amount of postoperative outflow through the fistula (after trabeculectomy) or membrane (after non-penetrating surgery) as well as the outflow through residual natural drainage pathways were calculated and compared. From our model, the following results were obtained: 1) if trabeculectomy is carried out in an eye with preoperative intraocular pressure (IOP) of 30 mm Hg and postoperative IOP=10 mm Hg, only 10% of aqueous utilizes the natural outflow pathway via the trabecular meshwork, whereas if non-penetrating surgery is carried out in the same eye with postoperative IOP=16 mm Hg, the outflow through the trabecular meshwork amounts to 35%. Thus, non-penetrating surgery provides more aqueous outflow along the natural outflow pathways than trabeculectomy. 2) Generally, the higher the postoperative IOP and/or the lower the preoperative IOP, the higher the amount of aqueous, which will utilize the natural outflow pathways postoperatively. 3) The reestablishment of aqueous production postoperatively in addition to other factors, such as wound healing, may be a reason for IOP increase during the postoperative period.
منابع مشابه
How does nonpenetrating glaucoma surgery work? Aqueous outflow resistance and glaucoma surgery.
Histologic, experimental, and theoretical studies of the aqueous outflow pathways point toward the juxtacanalicular region and inner wall of Schlemm's canal as the likely site of aqueous outflow resistance in the normal eye. At least 50% of the aqueous outflow resistance in the normal eye and the bulk of the pathologically increased resistance in the glaucomatous eye resides in the trabecular m...
متن کاملFurther Explorations of Aqueous Humour Drainage in Enucleated Human and Bovine Eyes
Primary open-angle glaucoma (POAG) is the most common form of glaucoma in individuals over forty-years of age in North America. In POAG, outflow resistance is pathologically elevated due to a malfunctioning or impairment of the filtration mechanisms with the eye; consequently, prolonged elevation of IOP may ultimately lead to irreversible blindness. The human eye appears to be particularly vuln...
متن کاملGlaucoma surgery and aqueous outflow: how does nonpenetrating glaucoma surgery work?
B LEBS. SHALLOW CHAMBERS. Bleb leaks. Flat chambers. Dellen. Blebitis. No bleb. Late failure. Hypotony. Choroidal effusions. Maculopathy. Is there a better way? If the problem is in the meshwork, why do we cut a hole in the eye? Viscocanalostomy and deep sclerectomy are surgical procedures for glaucoma that have been designed to avoid some of the complications of conventional glaucoma surgery. ...
متن کاملSecondary glaucoma due to anterior chamber lipoma and uveitis in a Pekingese dog
The present study introduces a rare case with secondary glaucoma due to anterior chamber lipoma and uveitis in a Pekingese dog in Iran. A four-year-old castrated male Pekingese dog was referred to the private clinic with impaired vision of the left eye, pain, rubbing the left eye onto carpet, presence of a milkycoloured mass into the anterior chamber, and loss of appetite. The clinical examinat...
متن کاملTrabeculectomy with internal tube shunt: a novel glaucoma surgery.
PURPOSE To describe a pilot study that evaluates the efficacy and mechanism of action of a new glaucoma operation, trabeculectomy with internal tube shunt. METHODS Twenty-three patients underwent the new operation in one eye for open angle glaucoma. Under a scleral flap, a deep sclerectomy was performed, resulting in an intrascleral lake. Laterally, on both sides, a small silicone tube was pl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedizinische Technik. Biomedical engineering
دوره 54 1 شماره
صفحات -
تاریخ انتشار 2009