Sinogram noise reduction for low-dose CT by statistics-based nonlinear filters [5747-241]
نویسندگان
چکیده
Low-dose CT (computed tomography) sinogram data have been shown to be signal-dependent with an analytical relationship between the sample mean and sample variance. Spatially-invariant low-pass linear filters, such as the Butterworth and Hanning filters, could not adequately handle the data noise and statistics-based nonlinear filters may be an alternative choice, in addition to other choices of minimizing cost functions on the noisy data. Anisotropic diffusion filter and nonlinear Gaussian filters chain (NLGC) are two well-known classes of nonlinear filters based on local statistics for the purpose of edge-preserving noise reduction. These two filters can utilize the noise properties of the low-dose CT sinogram for adaptive noise reduction, but can not incorporate signal correlative information for an optimal regularized solution. Our previously-developed Karhunen-Loève (KL) domain PWLS (penalized weighted least square) minimization considers the signal correlation via the KL strategy and seeks the PWLS cost function minimization for an optimal regularized solution for each KL component, i.e., adaptive to the KL components. This work compared the nonlinear filters with the KL-PWLS framework for low-dose CT application. Furthermore, we investigated the nonlinear filters for post KL-PWLS noise treatment in the sinogram space, where the filters were applied after ramp operation on the KL-PWLS treated sinogram data prior to backprojection operation (for image reconstruction). By both computer simulation and experimental low-dose CT data, the nonlinear filters could not outperform the KL-PWLS framework. The gain of post KL-PWLS edge-preserving noise filtering in the sinogram space is not significant, even the noise has been modulated by the ramp operation.
منابع مشابه
Penalized Weighted Least-Squares Approach for Low-Dose X- Ray Computed Tomography
The noise of low-dose computed tomography (CT) sinogram follows approximately a Gaussian distribution with nonlinear dependence between the sample mean and variance. The noise is statistically uncorrelated among detector bins at any view angle. However the correlation coefficient matrix of data signal indicates a strong signal correlation among neighboring views. Based on above observations, Ka...
متن کاملSNR-weighted Sinogram Smoothing with Improved Noise-resolution Properties for Low-dose X-ray Computed Tomography
To treat the noise in low-dose x-ray CT projection data more accurately, analysis of the noise properties of the data and development of a corresponding efficient noise treatment method are two major problems to be addressed. In order to obtain an accurate and realistic model to describe the x-ray CT system, we acquired thousands of repeated measurements on different phantoms at several fixed s...
متن کاملExperimental Investigation of Angular Stackgram Filtering for Noise Reduction of SPECT Projection Data: Study with Linear and Nonlinear Filters
We discuss data filtering prior to image reconstruction. For this kind of filtering, the radial direction of the sinogram is routinely employed. Recently, we have introduced an alternative approach to sinogram data processing, exploiting the angular information in a novel way. This new stackgram representation can be regarded as an intermediate form of the sinogram and image domains. In this ex...
متن کاملSR-NLM: A sinogram restoration induced non-local means image filtering for low-dose computed tomography
Radiation dose has raised significant concerns to patients and operators in modern X-ray computed tomography (CT) examinations. A simple and cost-effective means to perform a low-dose CT scan is to lower the milliampere-seconds (mAs) as low as reasonably achievable in data acquisition. However, the associated image quality with lower-mAs scans (or low-dose scans) will be unavoidably degraded du...
متن کاملAdaptive Noise Reduction toward Low-dose Computed Tomography
An efficient noise treatment scheme has been developed to achieve low-dose CT diagnosis based on currently available CT hardware and image reconstruction technologies. The scheme proposed includes two main parts: filtering in sinogram domain and smoothing in image domain. The acquired projection sinograms were first treated by our previously proposed Karhunen-Loeve (K-L) domain penalized weight...
متن کامل