Optimization of solid-phase microextraction sampling for analysis of volatile compounds emitted from oestrous urine of mares.

نویسندگان

  • Raimondas Mozūraitis
  • Vincas Būda
  • Anna-Karin Borg-Karlson
چکیده

The solid-phase microextraction (SPME) technique was applied and optimized for collection of volatile compounds emitted from oestrous urine of mares Equs cabalus L. (Perissodactyla, Equidae) for GC-MS analyses. Variables such as type of SPME fibre, collection time of volatiles, and addition of salt were optimized to improve the sampling efficiency in two aspects: extent and selectivity of absorption/adsorption of urine volatiles onto SPME fibres. The data revealed that the number of volatiles and the total amount represented as quantitative peak areas of the compounds trapped on fibres coated either with polydimethylsiloxane-divinylbenzene or with divinylbenzene-carboxen-polydimethylsiloxane were significantly higher compared to those coated with polydimethylsiloxane, polyacrylate, and carbowax-divinylbenzene. The polydimethylsiloxane-divinylbenzene-type of fibre coating was chosen for optimization of sampling time and effect of salt addition. Sampling periods lasted for 15, 30, 60, 120, and 240 min. The optimal collection time of volatiles from urine maintained at about 36 degrees C was 60 min, as the number of compounds detected with amounts sufficient for quantification did not differ significantly from those trapped during longer collection periods. No significant increase in total amount of volatiles trapped was registered after 120 min of sampling. Addition of 0.3 g NaCl to the 2-ml of samples shortened the collection period from 60 to 15 min during which almost all compounds were trapped. Addition of salt has a significant effect at all sampling periods taking into consideration the total amounts of volatiles trapped. The total intensities increased about 8, 5, 3, 3, and 2 times at collection periods of 15, 30, 60, 120, and 240 min, respectively, when compare with the ones obtained from the urine samples with no salt addition. In oestrous mare's urine, 139 +/- 4 (average number +/- standard deviation) volatile compounds suitable for quantitative analyses were detected compared to 45 compounds collected by the gas-tight syringe method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review

Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...

متن کامل

ZnO polythiophene SBA-15 nanoparticles as a solid-phase microextraction fiber for fast determination essential oils of Matricaria chamomilla

The objective of this study is determination the volatile compounds of Matricaria chamomilla of an inorganic–organic hybrid material based on ZnO nanoparticles anchored to a composite made from polythiophene and hexagonally ordered silica (ZnO/PT/SBA-15) as a solid-phase fiber microextraction (SPME). Microextraction techniques with nanoparticles ZnO/PT/SBA-15 resulted in a more efficient analyt...

متن کامل

Analysis of flavor volatiles of some Iranian rice cultivars by SPME-GC-MS

A combined gas chromatography–mass spectrometry (GC–MS) with headspace solid-phase microextraction (HS-SPME) method has been employed for the analysis of the flavor volatiles of some Iranian rice cultivars (Domsiah, Deylamani, Hashemi, Shirodi and Tarom). The samples were grown in different cities of Mazandaran province. The sampling procedure and chromatographic conditions were same for all sa...

متن کامل

Ordered Nanoporous Carbon Based Solid-Phase Microextraction for the Analysis of Nitroaromatic Compounds in Aqueous Samples

In this paper, the possibility of using a new ordered nanoporous carbon as a new fiber in headspace solid phase microextraction (HS-SPME) to determine of mononitrotoluenes (MNTs) in waste water is demonstrated. The structural order and textural properties of the ordered nanoporous carbon were studied by X Ray Diffraction (XRD), Scanning Electron Microscopy (SEM) images and nitrogen adsorpti...

متن کامل

p- and m-Cresols emitted from estrous urine are reliable volatile chemical markers of ovulation in mares.

Urine samples from 14 mares, belonging to five breeds, were collected at estrus and diestrus to search for estrous specific volatile compounds which could be used to determine ovulation time. Around 150 volatiles were collected from urine head-space samples by solid phase micro extraction technique, and analyses were conducted by gas chromatography-mass spectrometry methods. Comparison of chrom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Zeitschrift fur Naturforschung. C, Journal of biosciences

دوره 65 1-2  شماره 

صفحات  -

تاریخ انتشار 2010