Cerebral aneurysm pulsation: do iterative reconstruction methods improve measurement accuracy in vivo?
نویسندگان
چکیده
BACKGROUND AND PURPOSE Electrocardiogram-gated 4D-CTA is a promising technique allowing new insight into aneurysm pathophysiology and possibly improving risk prediction of cerebral aneurysms. Due to the extremely small pulsational excursions (<0.1 mm in diameter), exact segmentation of the aneurysms is of critical importance. In vitro examinations have shown improvement of the accuracy of vessel delineation by iterative reconstruction methods. We hypothesized that this improvement shows a measurable effect on aneurysm pulsations in vivo. MATERIALS AND METHODS Ten patients with cerebral aneurysms underwent 4D-CTA. Images were reconstructed with filtered back-projection and iterative reconstruction. The following parameters were compared between both groups: image noise, absolute aneurysm volumes, pulsatility, and sharpness of aneurysm edges. RESULTS In iterative reconstruction images, noise was significantly reduced (mean, 9.8 ± 4.0 Hounsfield units versus 8.0 ± 2.5 Hounsfield units; P = .04), but the sharpness of aneurysm edges just missed statistical significance (mean, 3.50 ± 0.49 mm versus 3.42 ± 0.49 mm; P = .06). Absolute volumes (mean, 456.1 ± 775.2 mm(3) versus 461.7 ± 789.9 mm(3); P = .31) and pulsatility (mean, 1.099 ± 0.088 mm(3) versus 1.095 ± 0.082 mm(3); P = .62) did not show a significant difference between iterative reconstruction and filtered back-projection images. CONCLUSIONS CT images reconstructed with iterative reconstruction methods show a tendency toward shorter vessel edges but do not affect absolute aneurysm volumes or pulsatility measurements in vivo.
منابع مشابه
Novel dynamic four-dimensional CT angiography revealing 2-type motions of cerebral arteries.
BACKGROUND AND PURPOSE We developed a novel dynamic 4-dimensional CT angiography to accurately evaluate dynamics in cerebral aneurysm. METHODS Dynamic 4-dimensional CT angiography achieved high-resolution 3-dimensional imaging with temporal resolution in a beating heart using dynamic scanning data sets reconstructed with a retrospective simulated R-R interval reconstruction algorithm. RESUL...
متن کاملIrretrievable signal loss in partial-Fourier acquired diffusion-weighted images
Introduction Diffusion weighted (DW) imaging is highly sensitive for bulk motion, which frequently occurs in vivo, such as in the lower brain areas, where the parenchyma pulsates rhythmically due to cardiac activity. It is known that for partial-Fourier (PF) imaging, the emergence of pulsation artefacts in DW images depends critically on the image reconstruction method. Specifically, it has bee...
متن کاملFeasibility of estimating regional mechanical properties of cerebral aneurysms in vivo.
PURPOSE In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS A data assimilation framework was developed to incorporate patient-specific geometries into a given biomechanical model, wh...
متن کاملTransradial Neurointerventional Approach to Basilar Tip Aneurysm: Case Report and Technical Note
Cerebral angiography through transfemoral approach is preferred in most of the situation though in cardiovascular surgery transradial angiography is accounted as the superior standard. The present study aimed at presenting our early experience of transradial approach to cerebral angiography and intervention of a patient with basilar tip aneurysm that had inappropriate vasculature to perform rou...
متن کاملEmploying dual frequency phase sensitive demodulation technique to improve the accuracy of voltage measurement in magnetic induction tomography and designing a labratoary prototype
Magnetic induction tomography (MIT) is a promising modality for noninvasive imaging due to its contactless technology. Being a non-contact safe imaging technique, MIT has been an appropriate method in compare to other electrical tomography. In this imaging method, a primary magnetic field is applied by excitation coils to induce eddy currents in the material to be studied and a secondary magnet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 35 11 شماره
صفحات -
تاریخ انتشار 2014