Characteristics, Accuracy and Reverification of Robotised Articulated Arm CMMs
نویسنده
چکیده
VDI article 2617 1 specifies characteristics to describe the accuracy of articulated arm coordinate measuring machines (AACMMs) and outlines procedures for checking them. However the VDI prescription was written with a former generation of machines in mind: manual arms exploiting traditional touch probe technologies. Recent advances in metrology have given rise to noncontact laser scanning tools and robotic automation of articulated arms – technologies which are not adequately characterised using the VDI specification. In this paper we examine the “guidelines” presented in VDI 2617, finding many of them to be ambiguous and open to interpretation, with some tests appearing even to be optional. The engineer is left significant flexibility in the execution of the test procedures and the manufacturer is free to specify many of the test parameters. Such flexibility renders the VDI tests of limited value and the results can be misleading. We illustrate, with examples using the Nikon RCA, how a liberal interpretation of the VDI guidelines can significantly improve accuracy characterisation and suggest ways in which to mitigate this problem. We propose a series of stringent tests and revised definitions, in the same vein as VDI 2617 and similar US standards, to clarify the accuracy characterisation process. The revised methodology includes modified acceptance and reverification tests which aim to accommodate emerging technologies, laser scanning devices in particular, while maintaining the spirit of the existing and established standards. We seek to supply robust re-definitions for the accepted terms “zero point” and “useful arm length”, presupposing nothing about the geometry of the measuring device. We also identify a source of error unique to robotised AACMMs employing laser scanners – the forwardreverse pass error. We show how eliminating this error significantly improves the repeatability of a device and propose a novel approach to the testing of probing error based on statistical uncertainty.
منابع مشابه
Modelling and Calibration Technique of Laser Triangulation Sensors for Integration in Robot Arms and Articulated Arm Coordinate Measuring Machines
A technique for intrinsic and extrinsic calibration of a laser triangulation sensor (LTS) integrated in an articulated arm coordinate measuring machine (AACMM) is presented in this paper. After applying a novel approach to the AACMM kinematic parameter identification problem, by means of a single calibration gauge object, a one-step calibration method to obtain both intrinsic-laser plane, CCD s...
متن کاملIntelligent Robotised Physiotherapy Tested on an 8-dof Mechatronic Arm
The successful rehabilitation of people with upper limb neuro-motor impairment depends largely on the appropriate selection and validation of a set of exercises. In this paper a knowledge-based system (KBS) for selecting a set of exercises to suit a particular patient status is proposed. Also a model of a mechatronic limb that simulates the human arm spastic characteristics will be developed. T...
متن کاملRadio Frequency Identification (RFID): A Technology for Enhancing Computerized Maintenance System (CMMS)
Abstract While Computerized Maintenance Management System (CMMS) enables maintenance managers and supervisors to access information about equipment, manpower and maintenance policies, there is still a need to facilitate getting data/information into the backend database where it can be utilized by the organization as information to make decisions regarding the operation of the organization. Si...
متن کاملThe use of parallel mechanism micro-CMM in micrometrology
Over the past two decades there has been a surge in demand for accurate and precise 3D metrology machines to provide measurements in micron scale. This demand is encouraged by the need for quality and process control for the promised technological development of micro electromechanical systems (MEMS). Parallel mechanisms have been the subject of study as positioning machines. Parallel manipulat...
متن کاملRobotic Calibration Issues: Accuracy, Repeatability and Calibration
The groundwork for a contact calibration methodology using a touch probe is developed for an articulated robot arm. This solution is framed within current calibration and metrology issues in robotics based upon the kinematical mechanical design of a serial link manipulator. Accuracy, repeatability, and resolution are explored and a simplistic approach is taken. This exercise is intended to lay ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010