Fast chemiluminescent measurement of RNA polymerase activity based on photon counting technology.

نویسندگان

  • N Walter
  • C Steiner
چکیده

A fast and simple assay for T7 RNA polymerase based upon chemiluminescent detection of the synthesized, digoxigenin-labeled RNA on a nylon membrane with anti-digoxigenin coupled alkaline phosphatase and CSPD as substrate is described. Activity of RNA polymerase is determined with high sensitivity by quantifying the emitted light of the microplate-formatted dot-blot membrane with a photon counting microplate luminometer and a specially designed filter adapter. The described method is one example for the application of this new adapter to measure luminescent membrane filters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nucleic Acid Quantification by Chemiluminescence Assay of Polymerase Chain Reaction Products

achieved by use of a chemiluminescent substrate, in conjunction with the TopCount in single photon counting (SPC), is comparable to that generated by isotopic methods, but without the associated handling hazards and disposal problems. Although the following protocol describes quantification of hepatitis C viral RNA (HCV-RNA), the principles of the method are of course applicable to the quantifi...

متن کامل

A Non-Demolition Photon Counting Method by Four-Level Inverted Y-Type Atom

The semi-classical model of atom-field interaction has been fully studied for some multilevel atoms, e.g. Vee, L, Cascade X , Y, and inverted Y and so on. This issue is developed into the full-quantum electrodynamics formalism, where the probe and coupling electromagnetic fields are quantized. In this article, we investigate the full-quantum model of absorption and dispersion spectrum of trappe...

متن کامل

Optimization of measurement counting time in Gamma-ray spectrometry of soil samples

The method of optimal measurement counting time in Gamma spectrometry for soil samples was studied. Gamma spectrometry was done based on minimum detectable activity using the HPGe- p type with efficiency of 30% and FWHM 1.7keV (for 1.33 MeV 60Co). The samples were IAEA-RG Th-1, IAEA-RGU-1 and IAEA-RGK-1 prepared in bottles. The measurements were done for 12 different counting times from 5 min t...

متن کامل

Neural Imaging Using Single-Photon Avalanche Diodes

Introduction: This paper analyses the ability of single-photon avalanche diodes (SPADs) for neural imaging. The current trend in the production of SPADs moves toward the minimumdark count rate (DCR) and maximum photon detection probability (PDP). Moreover, the jitter response which is the main measurement characteristic for the timing uncertainty is progressing. Methods: The neural imaging pro...

متن کامل

A Photon - Counting Array Detector System for Fast and Sensitive Analysis of Protein Microarrays

Fluorescence measurements on protein microarrays demand photodetectors with ultra-high sensitivity, low noise and parallel readout capability. A novel compact instrument capable of ultra-sensitive analysis of multiple proteins in a customized microarray has been designed and implemented. This system is based on a monolithic 6×8 array of single photon avalanche diodes (SPADs). The SPAD detector ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioTechniques

دوره 15 5  شماره 

صفحات  -

تاریخ انتشار 1993