Soft tissue fixation to bone. A biomechanical analysis of spiked washers.
نویسندگان
چکیده
The initial fixation strengths of two spiked-washer designs were evaluated using human femurs and fascia lata tissue. Fascia lata was attached to the femur using the fixation devices, and then each femur-washer-fascia lata complex was loaded in tension to failure. Load-elongation curves were recorded, the initial failure load, initial failure displacement, stiffness, ultimate load, and ultimate displacement were determined for each test, and failure modes were recorded. Results indicated that the 6-spike design provided superior initial fixation strength in the 19-mm diameter size. This washer design was then compared with two commercially available fixation devices: the spiked AO washer and soft tissue fixation plate. Fixation provided by the prototypal washer design was not different in most instances from that provided by the AO fixation devices. Based on these results, important design characteristics for soft tissue spiked washers are identified and discussed.
منابع مشابه
Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملStructural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts.
This study compared the stiffness (K), yield load (YL), and slippage (SL) of six tibial fixation methods. These properties were determined from load-to-failure and cyclic tests of double-looped tendon grafts fixed to both animal and young human tissue. Tandem washers (K = 259 N/mm, YL = 1159 N, SL = 0.5 mm) and the Washerloc (K = 248 N/mm, YL = 905 N, SL = 2.0 mm) were the two best fixations. A...
متن کاملACL Reconstruction Using a Short Hamstring Graft and Tape Locking Screw: A Biomechanical Study
Introduction: Anterior cruciate ligament (ACL) reconstruction is one of the most widely performed orthopaedic procedures in developed counties. Reconstruction using autograft soft tissue such as hamstring tendon has been the preferred choice by many for its superior strength and less donor-site morbidity over the bone-tendon-bone graft. Fixation of soft tissue graft, however, has been less than...
متن کاملFoam-reinforced elderly human tibia approximates young human tibia better than porcine tibia: a study of the structural properties of three soft tissue fixation devices.
BACKGROUND Because there is an insufficient supply of young human knees, an alternative is needed for evaluating anterior cruciate ligament reconstructions. The authors determined whether an elderly human tibia reinforced with foam is a better substitute for a young human tibia than a porcine tibia in this study of the tibialfixation of a soft tissue anterior cruciate ligament graft using 3 dev...
متن کاملChallenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem
The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of sports medicine
دوره 22 3 شماره
صفحات -
تاریخ انتشار 1994