Silk flow-diverter stent for the treatment of intracranial aneurysms: a series of 58 patients with emphasis on long-term results.

نویسندگان

  • B Lubicz
  • O Van der Elst
  • L Collignon
  • B Mine
  • F Alghamdi
چکیده

BACKGROUND AND PURPOSE The Silk flow-diverter stent is increasingly used to treat complex intracranial aneurysms including wide-neck, fusiform aneurysms. Sparse data are available concerning long-term results of this technique. We report our 5-year experience with Silk stent treatment of intracranial aneurysms. MATERIALS AND METHODS A retrospective review of our prospectively maintained database identified all patients treated by the Silk stent in 2 institutions. Clinical charts, procedural data, and angiographic results were reviewed. RESULTS Between July 2009 and May 2014, we identified 58 patients with 70 intracranial aneurysms. Endovascular treatment was successful in 93% of patients with 32 treated with the first-generation Silk stent and 26 with the new Silk+ stent. Mean follow-up in 47 patients was 22 months. Despite an 11% delayed complication rate, overall permanent neurologic morbidity was 5.5%. All complications were seen with the first-generation Silk stent. There was no procedure-related mortality. Long-term anatomic results showed 73% with complete occlusion, 16% with neck remnants, and 11% with incomplete occlusion. No recanalization or retreatment was performed. The midterm intrastent stenosis rate was 57%, of which 60% improved or disappeared, 28% were stable, and 12% led to vessel occlusion. Seventy-four percent of stenosis and all vessel occlusions occurred with the first-generation Silk stent. CONCLUSIONS Endovascular treatment of complex intracranial aneurysms with the Silk stent is an effective therapeutic option. Despite a high rate of delayed complications with the first-generation stents, the current Silk+ stent appears safer. This treatment achieves a high rate of adequate and stable occlusion at long-term follow-up.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endovascular Treatment of Intracranial Anterior Circulation Aneurysms with Flow Diverters: A Single Centre Experience with mid and long-term results.

AIM We report our experience with flow diverter devices in the treatment of intracranial aneurysms arising from anterior circulation with mid and long-term follow-up. MATERIAL AND METHODS 78 aneurysms in 61 patients (range 25-81 years, 13 male, 48 female) were treated with flow diverter devices. 40 (51,3%) aneurysms were treated with pipeline embolization device (PED), 24 (30,8%) aneurysms we...

متن کامل

Flow-Diverter Stent for the Endovascular Treatment of Intracranial Aneurysms

Background and Purpose—The purpose of this study is to report our preliminary experience with the flow-diverter Silk stent for the endovascular treatment of intracranial aneurysms. Methods—This prospective study was approved by the authors’ ethical committees. Twenty-nine patients with 34 fusiform or wide-necked unruptured aneurysms were included and treated by Silk stent placement alone by 2 p...

متن کامل

Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms.

BACKGROUND AND PURPOSE The purpose of this study is to report our preliminary experience with the flow-diverter Silk stent for the endovascular treatment of intracranial aneurysms. METHODS This prospective study was approved by the authors' ethical committees. Twenty-nine patients with 34 fusiform or wide-necked unruptured aneurysms were included and treated by Silk stent placement alone by 2...

متن کامل

Treatment of Intracranial Aneurysms With the SILK Embolization Device in a Multicenter Study. A Retrospective Data Analysis

BACKGROUND Flow-diverter technology has become an important stent-based embolization tool in the treatment of complex cerebrovascular pathology. We report here the experience of 4 Spanish centers with using the SILK flow-diverter (SFD) device. OBJECTIVE To evaluate the safety and efficacy of using the SFD in the endovascular treatment of intracranial aneurysms with complex morphology. METHO...

متن کامل

Silk Device for the Treatment of Intracranial Aneurysms. Part 1: Peri-Procedural Results, Technical Aspects and Learning Curve.

AIM We evaluated the procedural outcomes of intracranial aneurysm treatment with the Silk device and its relation with operator experience. We also detailed some technical points we learned throughout our experience. MATERIAL AND METHODS One hundred and six consecutive patients with intracranial aneurysms treated using Silk (BaltExtrusion, Montmorency, France) stent between October 2010 and N...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 36 3  شماره 

صفحات  -

تاریخ انتشار 2015