Ceramic liner fatigue fracture: 3-D CT findings in a late recurrent THA dislocation.

نویسندگان

  • Giacomo Trivellin
  • Andrea Sandri
  • Nicola Bizzotto
  • Marco Andrea Marino
  • Silvio Mezzari
  • Elena Sambugaro
  • Dario Regis
چکیده

Dislocation is one of the most common complications of total hip arthroplasty (THA). To the authors' knowledge, late recurrent dislocation of a THA with a ceramic-on-ceramic coupling secondary to fatigue fracture of the ceramic liner has never been described. A 76-year-old woman with right hip osteoarthritis underwent cementless modular THA with a ceramic-on-ceramic coupling. Approximately 10 years postoperatively, she experienced right hip pain with no trauma, which resolved in 14 days. Family members reported that the patient had shown a progressive cognitive and muscular decline in the previous months. Six months later, the patient was admitted for THA dislocation, which was immediately reduced. Computed tomography revealed that the right acetabular component had a retroversion of 4° and an inclination angle of 45°. An orthopedic brace was applied, but dislocation recurred 2 days after discharge. A 3-dimensional CT reconstruction showed a fracture of the ceramic liner in the posterolateral region. The patient underwent revision surgery, and the ceramic liner breakage was confirmed. After removal of the acetabular components, a cemented polyethylene cup was implanted. The stability of the stem was verified. The existing modular neck was replaced with a chromium-cobalt neck, and a new ceramic head was applied. At 7-month follow-up, the patient had good functional recovery with no hip instability. Fatigue failure of a ceramic liner should be considered as responsible for late dislocation after ceramic-on-ceramic THA. As part of the diagnostic strategy, 3-dimensional CT reconstruction should be used to evaluate ceramic liner breakage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component

The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a m...

متن کامل

Late Anterior Dislocation Due to Posterior Pelvic Tilt in Total Hip Arthroplasty

BACKGROUND Excessive pelvic tilt may be one of the factors leading to instability in total hip arthroplasty (THA), even when the acetabular cup is placed properly. To our knowledge, only a few studies have described late anterior dislocation due to posterior pelvic tilt. We present 3 cases with late anterior dislocations possibly due to posterior pelvic tilt. CASES PRESENTATIONS Case-1: An 84...

متن کامل

Early Intraprosthetic Dislocation of Dual- Mobility Total Hip Arthroplasty Implant Following Attempted Closed Reduction: A Case Report

Introduced in 1974 by Bousquet, the dual-mobility bearing for use in total hip arthroplasty (THA) confers increased jump distance and improved overall stability relative to conventional THA designs [1-3]. The dual-mobility bearing incorporates a relatively small (22-28mm) metal or ceramic femoral head press fit into a larger polyethylene liner which articulates with the acetabular component. Di...

متن کامل

A late dissociation of the ceramic component of a sandwich liner cup in a total hip arthroplasty—Case report and review of the literature

We present a case of a 71-year-old woman with unexplained instability of her total hip arthroplasty 12 years after implantation due to loosening of the ceramic component of a sandwich ceramic in polyethylene liner. She experienced in total 2 dislocations in 6 months. These events occurred without fracture of the ceramic liner. Sandwich ceramic liners were introduced with the idea of combining t...

متن کامل

Ceramic Total Hip Liner Fracture Modeling in Abaqus using co-Simulation and Extended Finite Element Modeling

Due to concerns over particle generation in conventional metal-on-polyethylene hip bearings used in total hip arthroplasty (THA), interest in advanced low-wear bearing alternatives such as ceramic-on-ceramic (CoC) couples has reemerged. While ceramics demonstrate excellent compressive strength, the brittle nature of the material reduces tensile strength, possibly leading to catastrophic fractur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2013