l-DOPA and Freezing of Gait in Parkinson’s Disease: Objective Assessment through a Wearable Wireless System

نویسندگان

  • Antonio Suppa
  • Ardian Kita
  • Giorgio Leodori
  • Alessandro Zampogna
  • Ettore Nicolini
  • Paolo Lorenzi
  • Rosario Rao
  • Fernanda Irrera
چکیده

Freezing of gait (FOG) is a leading cause of falls and fractures in Parkinson's disease (PD). The episodic and rather unpredictable occurrence of FOG, coupled with the variable response to l-DOPA of this gait disorder, makes the objective evaluation of FOG severity a major clinical challenge in the therapeutic management of patients with PD. The aim of this study was to examine and compare gait, clinically and objectively, in patients with PD, with and without FOG, by means of a new wearable system. We also assessed the effect of l-DOPA on FOG severity and specific spatiotemporal gait parameters in patients with and without FOG. To this purpose, we recruited 28 patients with FOG, 16 patients without FOG, and 16 healthy subjects. In all participants, gait was evaluated clinically by video recordings and objectively by means of the wearable wireless system, during a modified 3-m Timed Up and Go (TUG) test. All patients performed the modified TUG test under and not under dopaminergic therapy (ON and OFF therapy). By comparing instrumental data with the clinical identification of FOG based on offline video-recordings, we also assessed the performance of the wearable system to detect FOG automatically in terms of sensitivity, specificity, positive and negative predictive values, and finally accuracy. TUG duration was longer in patients than in controls, and the amount of gait abnormalities was prominent in patients with FOG compared with those without FOG. l-DOPA improved gait significantly in patients with PD and particularly in patients with FOG mainly by reducing FOG duration and increasing specific spatiotemporal gait parameters. Finally, the overall wireless system performance in automatic FOG detection was characterized by excellent sensitivity (93.41%), specificity (98.51%), positive predictive value (89.55%), negative predictive value (97.31%), and finally accuracy (98.51%). Our study overall provides new information on the beneficial effect of l-DOPA on FOG severity and specific spatiotemporal gait parameters as objectively measured by a wearable sensory system. The algorithm here reported potentially opens to objective long-time sensing of FOG episodes in patients with PD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wireless Sensing System for Long-Time Assistance in the Parkinson’s Disease

A non-invasive wearable wireless sensing system for assisting patients affected by Parkinson’s Disease is proposed. It uses inertial sensors to recognize gait states and involuntary gait freezing. The system is designed for indoor and outdoor long-time monitoring and realizes an individual electronic diary useful for doctors for estimating better the stage of the disease and customizing the pha...

متن کامل

Posture Detection with waist-worn Accelerometer: An application to improve Freezing of Gait detection in Parkinson’s disease patients

Freezing of Gait (FoG) is one of the most disturbing symptoms in Parkinson’s disease (PD). Current algorithms that detect this symptom depend on frequency features extracted from wearable systems. These algorithms have only been evaluated under laboratory conditions and, in real life, they might present false positives, reducing the reliability of the algorithm. This paper presents the evaluati...

متن کامل

deFOG--A real time system for detection and unfreezing of gait of Parkinson's patients.

Freezing of gait (FOG) is a common complication in movement disorders, typically associated with the advanced stages of Parkinson's disease. Auditory cues might be used to facilitate unfreezing of gait and prevent fall related injuries. We present a wearable, unobtrusive system for real-time gait monitoring, which consists of an inertial wearable sensor and wireless headset for the delivery of ...

متن کامل

Relation of 18-F-Dopa PET with hypokinesia-rigidity, tremor and freezing in Parkinson’s disease

INTRODUCTION In this retrospective study concerning patients with Parkinson's disease (PD) scanned with 18-F-Dopa PET (N = 129), we looked for an association between reduced 18-F-Dopa uptake and the key PD symptoms tremor and hypokinesia-rigidity. We hypothesized to find a stronger correlation between dopaminergic depletion in the striatum and hypokinesia-rigidity compared to tremor. METHODS ...

متن کامل

Ambient Sensor System for Freezing of Gait Detection by Spatial Context Analysis

Freezing of gait (FoG) is one of the most disturbing and least understood symptoms in Parkinson’s disease (PD). One of the specificities of FoG is its dependency on the context of the patient, such as current location or a task at hand. Recent advances in assistive technology have strived towards the realization of personal health systems able to prolong independent living capability of people ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017