Retention of CAD/CAM all-ceramic crowns on prefabricated implant abutments: an in vitro comparative study of luting agents and abutment surface area.
نویسندگان
چکیده
PURPOSE Previous studies considering retention of cast metal restorations to implant abutments incorporated some degree of frictional fit due to internal surface nodules and roughness of the restoration. In comparison, CAD/CAM restorations have minimal surface irregularities, possibly impacting retention. There is insufficient knowledge of retentive force of CAD/CAM restorations to titanium abutments, and therefore the topic warrants further investigation. This in vitro study investigated the retention of all-ceramic CAD/CAM restorations to three different prefabricated implant abutments using five different cements. MATERIALS AND METHODS A total of 150 Astra Tech dental implant abutments were used, with each group of 50 being subdivided into five groups of 10. An optical impression of each size of abutment was made with the CEREC 3D intraoral camera. A full-coverage restoration was designed and milled with an enlarged, conical-shaped occlusal surface, which served to secure the restoration into a brass jig used with a universal testing machine. Five different cements were used with three different-sized abutments. Following cementation, the implant/abutment/restoration assemblies were stored for 24 hours at 37°C in 100% humidity. A pull-out test using a universal testing machine, set at a 0.5 mm/min crosshead speed, was used to evaluate retention of the individual restorations. The load required to remove each all-ceramic restoration was recorded. Retention values were analyzed using ANOVA and Fisher's PLSD multiple comparisons test at the 0.05 level of significance. RESULTS Peak loads for two provisional cements and a resin-modified glass ionomer cement ranged from 56 N to 127 N. Peak loads for two resin cements ranged from 184 N to 318 N. Two-way ANOVA showed significant effects upon retentive forces for both the cement and abutment design. Post hoc Fisher's PLSD multiple comparisons test found significant differences in retention for 7 of the 10 pairings of cements at a 0.05 level of significance. In addition, Fisher's PLSD multiple comparisons test found significant differences between Astra Tech Direct Abutments 4 and Astra Tech Direct Abutments 5 as well as Astra Tech Direct Abutments 4 and Astra Tech Direct Abutments 6 at a 0.05 level of significance. No significant difference was found between Astra Tech Direct Abutments 5 and Astra Tech Direct Abutments 6. CONCLUSIONS Of the five cements tested, the most retrievable CAD/CAM restorations were luted with Temp Bond NE and Improv Temporary Cement. Resin-modified glass ionomer retentive forces were closer to those of the "temporary cements" than those of the permanent adhesive-resin cements. The abutment surface area became less important when using adhesive-resin cements. Retention of CAD/CAM all-ceramic restorations to prefabricated abutments has not been reported in the literature. This in vitro study demonstrated clinically significant variation among the selected cements used to retain all-ceramic CAD/CAM restorations to implant abutments. In addition, abutment size influenced the retention of all-ceramic CAD/CAM restorations.
منابع مشابه
The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement
Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI), 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughen...
متن کاملCAD/CAM to fabricate ceramic implant abutments and crowns: a preliminary in vitro study.
BACKGROUND This study evaluated the feasibility of fabricating implant abutments and crowns from pre-sintered feldspathic porcelain blocks using the chair-side CAD/CAM, CEREC3D((R)) system. METHODS Thirty-two implant analogues were divided into two groups. In the control group, prefabricated machined anatomical titanium (Ti) abutments were screw-retained to the analogues. In the test group, m...
متن کاملRetentive strength of two-piece CAD/CAM zirconia implant abutments.
PURPOSE The purpose of this study is to evaluate the retention of two-piece computer-aided design (CAD)/computer aided manufacturing (CAM) zirconia abutments after artificial aging under simulated oral conditions using three different types of resin-based luting agents. MATERIAL AND METHODS Twenty-one CAD/CAM-generated zirconia copings (CERCON Compartis, Degudent, Hanau, Germany) were bonded ...
متن کاملEffect of Abutment Modification and Cement Type on Retention of Cement-Retained Implant Supported Crowns
OBJECTIVE Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations. MATERIALS AND M...
متن کاملRetentiveness of dental cements used with metallic implant components.
There is limited dental literature evaluating the retentive capabilities of luting agents when used between metal components, such as cast metal restorations cemented onto machined metal implant abutments. This study compared the retentive strengths of 5 different classes of luting agents used to cement cast noble metal alloy crowns to 8-degree machined titanium cementable implant abutments fro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of prosthodontics : official journal of the American College of Prosthodontists
دوره 21 7 شماره
صفحات -
تاریخ انتشار 2012