Intensity-based Registration of Portal Images for Patient Positioning in Radiotherapy

نویسندگان

  • C. LE VERRE
  • J. TROCCAZ
  • X. ARTIGNAN
  • M. BOLLA
چکیده

Radiotherapy is the second most frequent type of cancer treatment after surgery and before chemotherapy. Its aim is to deliver a lethal dose to the tumour with high-energy X-rays produced by a medical linear accelerator, while sparing surrounding healthy tissue. To improve the effectiveness of X-rays, the treatment is fractioned in several sessions (e.g. five sessions per week during six or seven weeks).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast DRR generation for intensity-based 2D/3D image registration in radiotherapy

Conformal radiotherapy requires accurate patient positioning according to a reference given by an initial 3D CT image. Patient setup is controlled with the help of portal images (PI), acquired just before patient treatment. To date, the comparison with the reference by physicians is mostly visual. Several automatic methods have been proposed, generally based on segmentation procedures. However,...

متن کامل

Treatment couch positioning uncertainties using an EPID-based method

Introduction: The accuracy of patient positioning plays an important role for radiotherapy tasks. Short and automated Quality Assurance (QA) programs are becoming one of the challenging tasks in Radiotherapy. The current study, investigates the accuracy of treatment couch positioning with four degrees of freedom (4DoF) using a fast and accurate method based on an image acquired...

متن کامل

Towards Automatic, Model-Driven Determination of 3D Patient Setup Errors in Conformal Radiotherapy

The accurate and quantitative determination of three-dimensional patient setup errors in conformal radiotherapy, including setup errors due to out-of-plane rotations, requires methods for registering pre-treatment, three-dimensional planning CT images with intra-treatment, two-dimensional portal images. We have developed a method for performing such a registration based on structural models tha...

متن کامل

Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy

The efficacy of radiation therapy treatment depends on the patient setup accuracy at each daily fraction. A significant problem is reproducing the patient position during treatment planning for every fraction of the treatment process. We propose and evaluate an intensity based automatic registration method using multiple portal images and the pre-treatment CT volume. We perform both geometric a...

متن کامل

Calculation of Inter- and Intra-Fraction Motion Errors at External Radiotherapy Using a Markerless Strategy Based on Image Registration Combined with Correlation Model

Introduction: A new method based on image registration technique and an intelligent correlation model to calculate. The present study aimed to propose inter- and intra-fraction motion errors in order to address the limitations of conventional Patient positioning methods. Material and Methods: The configuration of the markerless method wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005