Factors related to the incorrect use of inhalers by asthma patients*

نویسندگان

  • Paulo de Tarso Roth Dalcin
  • Denis Maltz Grutcki
  • Paola Paganella Laporte
  • Paula Borges de Lima
  • Samuel Millán Menegotto
  • Rosemary Petrik Pereira
  • Paula Borges de Lima
چکیده

OBJECTIVE To evaluate inhaler technique in outpatients with asthma and to determine associations between the correctness of that technique and the level of asthma control. METHODS This was a cross-sectional study involving patients > 14 years of age with physician-diagnosed asthma. The patients were recruited from the Asthma Outpatient Clinic of the Hospital de Clínicas de Porto Alegre, in the city of Porto Alegre, Brazil. The patients completed two questionnaires (a general questionnaire and an asthma control questionnaire based on the 2011 Global Initiative for Asthma guidelines), demonstrated their inhaler technique, and performed pulmonary function tests. Incorrect inhaler technique was defined as the incorrect execution of at least two of the predefined steps. RESULTS We included 268 patients. Of those, 81 (30.2%) showed incorrect inhaler technique, which was associated with poor asthma control (p = 0.002). Logistic regression analysis identified the following factors associated with incorrect inhaler technique: being widowed (OR = 5.01; 95% CI, 1.74-14.41; p = 0.003); using metered dose inhalers (OR = 1.58; 95% CI, 1.35-1.85; p < 0.001); having a monthly family income < 3 times the minimum wage (OR = 2.67; 95% CI, 1.35-1.85; p = 0.008), and having > 2 comorbidities (OR = 3.80; 95% CI, 1.03-14.02; p = 0.045). CONCLUSIONS In the sample studied, incorrect inhaler technique was associated with poor asthma control. Widowhood, use of metered dose inhalers, low socioeconomic level, and the presence of > 2 comorbidities were associated with incorrect inhaler technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Usage Pattern, Satisfaction, Causes of Concern and Related Factors of Metered Dose Inhalers in Children with Asthma, the Parents Perspective

Introduction  Metered Dose Inhalers (MDIs) are the most common drugs for the control of asthma. This study was conducted to evaluate usage patterns, satisfaction with and concerns about MDIs for children with asthma and the related factors from the viewpoints’ of their parents. Materials and methods This cross-sectional study was conducted on children with asthma who referred to asthma and a...

متن کامل

Evaluation of Inhaler Techniques Among Asthma Patients Seen in Nigeria: An Observational Cross Sectional Study

BACKGROUND An Adequate and an effective dose of inhalation drugs can be administered only if the correct inhaler-specific technique is followed by asthma patients. There is paucity of data on this subject among Nigerians and Africans. AIMS This observational study was to assess the inhaler techniques among asthma patients in Nigeria and also to identify the factors related to an inaccurate or...

متن کامل

Comparison of Seroflu and Seretide Inhalers on Spirometry Criteria and Clinical Symptoms in Patients with Severe and Moderate Asthma

Background and purpose: Asthma is one of the most prevalent chronic respiratory diseases which has become more prevalent over the past three decades. Seroflo and Seretide are inhalers that contain fluticasone (an anti-inflammatory corticosteroid) and salmeterol (a long-acting bronchodilator). This study aimed to compare the effects of Seroflo and Seretide nasal sprays on spirometry criteria and...

متن کامل

Incorrect use of pressurised metered dose inhaler by asthmatic patients.

The use of pressurised metered dose inhalers was assessed among 93 asthmatic patients attending the respiratory out patient clinic between January to October 1989. They were regular users of the inhalers prior to the assessment. 62.4% of the patients were found to use the inhalers incorrectly. Forty three percent made more than one error. The commonest error observed was the failure to actuate ...

متن کامل

Development of a conceptual model for asthma management system in primary care

Introduction: Asthma is uncontrolled in more than half of asthma patients due to inadequate and incorrect management. The main reasons for inadequate management are non-adherence, inadequate knowledge of a general practitioner about patientchr('39')s clinical condition, and not following asthma management guidelines The purpose of this study was to develop a conceptual model for the asthma mana...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 40  شماره 

صفحات  -

تاریخ انتشار 2014