Quantification of the fraction poorly deformable red blood cells using ektacytometry.
نویسندگان
چکیده
We describe a method to obtain the fraction of poorly deformable red blood cells in a blood sample from the intensity pattern in an ektacytometer. In an ektacytometer red blood cells are transformed into ellipsoids by a shear flow between two transparent cylinders. The intensity pattern, due to a laser beam that is sent through the suspension, is projected on a screen. When measuring a healthy red blood cell population iso-intensity curves are ellipses with an axial ratio equal to that of the average red blood cell. In contrast poorly deformable cells result in circular iso-intensity curves. In this study we show that for mixtures of deformable and poorly deformable red blood cells, iso-intensity curves in the composite intensity pattern are neither elliptical nor circular but obtain cross-like shapes. We propose a method to obtain the fraction of poorly deformable red blood cells from those intensity patterns. Experiments with mixtures of poorly deformable and deformable red blood cells validate the method and demonstrate its accuracy. In a clinical setting our approach is potentially of great value for the detection of the fraction of sickle cells in blood samples of patients with sickle cell disease or to find a measure for the parasitemia in patients infected with malaria.
منابع مشابه
The relationship between red blood cell deformability metrics and perfusion of an artificial microvascular network.
The ability of red blood cells (RBC) to undergo a wide range of deformations while traversing the microvasculature is crucial for adequate perfusion. Interpretation of RBC deformability measurements performed in vitro in the context of microvascular perfusion has been notoriously difficult. This study compares the measurements of RBC deformability performed using micropore filtration and ektacy...
متن کاملMeasuring Deformability and Red Cell Heterogeneity in Blood by Ektacytometry.
Decreased red cell deformability is characteristic of several disorders. In some cases, the extent of defective deformability can predict severity of disease or occurrence of serious complications. Ektacytometry uses laser diffraction viscometry to measure the deformability of red blood cells subject to either increasing shear stress or an osmotic gradient at a constant value of applied shear s...
متن کاملGreater erythrocyte deformability in world-class endurance athletes.
Because athletes during endurance events require rapid uptake of oxygen, the ability of red blood cells (RBC) to move through capillaries may limit performance. Using ektacytometry, we determined whether RBC deformability (RCD) differed between elite road cyclists ( n = 9) and sedentary controls ( n = 5). Density profiles and standard hematological measurements were also performed. The deformab...
متن کاملRed Blood Cell Mechanical Stability
It has been well documented that shear forces effective above a certain magnitude under flow conditions causes damage in blood cells. This damage ranges from slight morphological alteration to the destruction of red blood cells (RBC). The hemolytic trauma to RBC can easily be detected by measuring free hemoglobin level in plasma, however there are no standardized protocols to quantitate subhemo...
متن کاملThe sensing of poorly deformable red blood cells by the human spleen can be mimicked in vitro.
Retention of poorly deformable red blood cells (RBCs) by the human spleen has been recognized as a critical determinant of pathogenesis in hereditary spherocytosis, malaria, and other RBC disorders. Using an ex vivo perfusion system, we had previously shown that retention of Plasmodium falciparum-infected RBCs (Pf-RBCs) occur in the splenic red pulp, upstream from the sinus wall. To experimenta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 18 13 شماره
صفحات -
تاریخ انتشار 2010