[The interaction between labor analgesia and its results: assessment using the newborn s weight and Apgar score.].

نویسندگان

  • Andrea Stolf Eberle
  • Eliana Marisa Ganem
  • Norma Sueli Pinheiro Módolo
  • Rosa Beatriz Amorim
  • Giane Nakamura
  • Christiane D'Oliveira Marques
  • Yara Marcondes Machado Castiglia
چکیده

BACKGROUND AND OBJECTIVES There are controversies regarding whether labor analgesia can interfere with labor and the vitality of the newborn. The objective of this study was the interaction between labor analgesia, using the continuous epidural and combined spinal-epidural techniques with a small dose of local anesthetic, and the type of delivery analyzing the newborn's weight and Apgar score. METHODS The results of 168 labor analgesias (from January 2002 to January 2003) were analyzed. They were divided in 4 groups: G1 (n = 58), continuous epidural and evolution to vaginal delivery; G2 (n = 69), combined spinal-epidural and evolution to vaginal delivery; G3 (n = 25), continuous epidural and evolution to cesarean; G4 (n = 16), combined spinal-epidural and evolution to cesarean. G1 received 0.125% ropivacaine (12 to 15 mL), G2 received subarachnoid 0.5% bupivacaine (0.5 to 1 mL) and sufentanil (10 mg). Epidural ropivacaine 0.5% for the vaginal delivery (8 mL) and for cesarean (20 mL). The patient's age, weight, height, body mass index (BMI), gestational age, number of prior pregnancies, and complications (arterial hypotension, bradycardia, and hypoxia) and the newborn's weight and Apgar score (at 1, 5, and 10 minutes) were evaluated. RESULTS The majority of pregnant women were primiparous and presented with a term pregnancy (one with gestational age of 28 weeks and none post-term pregnancy); weight, G2 < G4; and MBI, G2 pound G4. For the weight of the newborn, G1 < G3 and G2 < G4, and for the Apgar score at 1st minute, G1 > G3. CONCLUSIONS If the analysis focuses the newborn's weight and Apgar score, the techniques of analgesia, continuous epidural and combined spinal-epidural with small doses of local anesthetic, do not interfere with the result of the delivery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is Epidural Analgesia a Predictor of Low Newborn Apgar? A Hospital-Based Observational Study

A painful labor induces adverse maternal effects and increases fetal stress, yet evidence of lack of adverse effect of epidural anesthesia to the newborn Apgar score has been inconsistent. The aim of this study was to investigate maternal, newborn and anesthetic factors associated with a low Apgar score, in particular the effect of modality and timing of epidural analgesia, since this may allow...

متن کامل

Intrathecal Analgesia Versus Non-analgesia in Labor on Maternal and Neonatal Outcomes

Aims: Spinal analgesia is the most common method that provides pain relief during labor and controversy exists about its effect on the maternal and fetal among the women. This study was conducted to determine the effect of intrathecal analgesia (ITA) on perineal laceration, duration of the first, second, and third stage of labor, and Apgar score. Materials & Methods: Fifty primipara parturien...

متن کامل

بررسی ارتباط بین طول مراحل زایمانی و نمره آپگار نوزاددر زنان نخست زا مراجعه کننده به زایشگاه بیمارستان امام خمینی ساری

  A correlational study was conducted to investigate the relationship between me duration of labor stages and the   newborn 's Apgar score in women admitted to Imam Khomeini Hospital (Sari 1994).   A total of 1 20 primigravida women admitted for delivery wert' selected sequentially. The tool was a checklist   consisting of three parts . The first part inquired as to certain demographic informat...

متن کامل

تاثیر استفاده از توپ زایمانی بر پیامدهای مادری و نوزادی:یک مطالعه کارآزمایی بالینی

Introduction: Using exercise with birth ball during labor leads to labor pain relief and improvement in the labor process, and is a very important non-medication method, looking into the chemical medications side-effects on mother and fetus, plus being affordable. This study aimed to investigate the effects of using birth ball on maternal and neonatal outcomes. Methods: In this clinical tr...

متن کامل

Comparison of Epidural versus Entonox for Labor Analgesia in Nulliparous Women

 Introduction: The aim of this study is to compare the efficacy of epidural versus entonox methods for labor analgesia in nulliparous women.  Methods: This randomized controlled trial was performed on 84 nulliparous women with - pregnancy admitted to Imam Reza Hospital in 10 May 2010- 10 May 2011.  They were randomly divided into two groups 42 women inhaled entonox in active phase at the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de anestesiologia

دوره 56 4  شماره 

صفحات  -

تاریخ انتشار 2006