Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging.

نویسندگان

  • Keivan Majidi
  • Jun Li
  • Carol Muehleman
  • Jovan G Brankov
چکیده

The analyzer-based phase-contrast x-ray imaging (ABI) method is emerging as a potential alternative to conventional radiography. Like many of the modern imaging techniques, ABI is a computed imaging method (meaning that images are calculated from raw data). ABI can simultaneously generate a number of planar parametric images containing information about absorption, refraction, and scattering properties of an object. These images are estimated from raw data acquired by measuring (sampling) the angular intensity profile of the x-ray beam passed through the object at different angular positions of the analyzer crystal. The noise in the estimated ABI parametric images depends upon imaging conditions like the source intensity (flux), measurements angular positions, object properties, and the estimation method. In this paper, we use the Cramér-Rao lower bound (CRLB) to quantify the noise properties in parametric images and to investigate the effect of source intensity, different analyzer-crystal angular positions and object properties on this bound, assuming a fixed radiation dose delivered to an object. The CRLB is the minimum bound for the variance of an unbiased estimator and defines the best noise performance that one can obtain regardless of which estimation method is used to estimate ABI parametric images. The main result of this paper is that the variance (hence the noise) in parametric images is directly proportional to the source intensity and only a limited number of analyzer-crystal angular measurements (eleven for uniform and three for optimal non-uniform) are required to get the best parametric images. The following angular measurements only spread the total dose to the measurements without improving or worsening CRLB, but the added measurements may improve parametric images by reducing estimation bias. Next, using CRLB we evaluate the multiple-image radiography, diffraction enhanced imaging and scatter diffraction enhanced imaging estimation techniques, though the proposed methodology can be used to evaluate any other ABI parametric image estimation technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

 A novel approach to automatic position calibration for pixelated crystals in gamma imaging

Introduction: The position estimation in gamma detection system will have constant misplacements which can be corrected in the calibration procedure. In the pixelated crystal uniformly irradiation of detector will produce irregular shape due to position estimation errors. This image is called flood field image and is used to calibrate the position estimation. In this work we pr...

متن کامل

Development of an X-Ray Interferometer for High-Resolution Phase-Contrast X-Ray Imaging

An X-ray interferometer for high-resolution phase-contrast X-ray imaging was developed by thinning the central part of the analyzer crystal of a triple Laue-case (LLL) X-ray interferometer. The interferometer was tested at beamline 47XU at the SPring-8, and the improvement of the resolution of interference patterns was successfully observed for a plastic sphere of 1 mm diameter.

متن کامل

Optimizing On-Wafer Noise Figure Measurements up to 67 GHz

Two techniques are commonly used to measure NF: the Y-factor method and the cold-source method. The Y-factor or hot/ cold-source method is the predominant approach and is most commonly implemented with noise-figure analyzers and spectrum analyzer-based solutions. In contrast, the cold-source method is usually performed using vector network analyzers (VNAs), which provide magnitude and phase inf...

متن کامل

Synchrotron high angular resolution microdiffraction analysis of selective area grown optoelectronic waveguide arrays

A synchrotron microbeam high-angular resolution diffraction setup based on a phase zone plate and a perfect Si(004) analyzer crystal was introduced to generate an x-ray microbeam with a lateral size of 0.24μm and an angular resolution of 2 arcsec. The microbeam high angular resolution x-ray diffraction was applied to study InGaAlAs-based multiple quantum well (MQW) ridge-waveguide arrays produc...

متن کامل

Temperature gradient analyzers for compact high-resolution X-ray spectrometers

Compact high-resolution X-ray spectrometers with a one-dimensional temperature gradient at the analyzer crystal are considered. This gradient, combined with the use of a position-sensitive detector, makes it possible to relax the usual Rowland-circle condition, allowing increased space at the sample position for a given energy resolution or arm radius. Thus, for example, it is estimated that ap...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 59 8  شماره 

صفحات  -

تاریخ انتشار 2014