Anterior Segment Optical Coherence Tomography Imaging of Filtering Blebs after Deep Sclerectomy with Esnoper-Clip Implant: One-year Follow-up
نویسندگان
چکیده
PURPOSE To describe the technique of deep sclerectomy with the new Esnoper-Clip® implant, the clinical outcome and the anatomic characteristics of filtering blebs, using anterior segment optical coherence tomography (AS-OCT). METHODS A prospective case-series study was conducted in five eyes (5 patients) with open angle glaucoma. The fornix-based deep sclerectomy with Esnoper-Clip® implant was done by the same surgeon. In one case, mitomycin C was used during surgery. All participants underwent a complete ophthalmic examination and AS-OCT (Visante®) preoperatively, then at each follow-up visit, at 1 day, 1 week, 1 month, 6 months and 1 year postoperatively. Scans were obtained through sagittal and transversal plans to the implant. RESULTS Intraocular pressure (IOP) was significantly reduced (p < 0.05) from a mean preoperative value of 23.4 ± 8.6 mm Hg (n = 3.8 glaucoma medications) to a postoperative value of 6.0 ± 2.5 (n = 0), 10.6 ± 5.4 (n = 0), 13 ± 1.6 (n = 0.4), 12.4 ± 2.1 (n = 0.2) and 14.4 ± 1.5 (n = 0.2) at 1 day, 1 week, 1 month, 6 months and 1 year respectively. AS-OCT allowed the visualization of the two plates of the implant (scleral and suprasciliary), the trabeculodescemetic membrane and the hyporeflective spaces in the bleb wall thickness and in suprascleral and suprachoroidal localizations. An immediate postoperative hypotony and an anteriorization of the implant associated to trabeculodescemetic membrane rupture, were detected, although without significant clinical repercussions. CONCLUSION Our first five deep sclerectomy with Esnoper-Clip implantation analysis suggest an effective and well-tolerated method to reduce IOP. AS-OCT is a noninvasive imaging technique that allows the anatomic analysis of the drainage mechanisms after glaucoma surgery. How to cite this article: Vieira L, Noronha M, Lemos V, Reina M, Gomes T. Anterior Segment Optical Coherence Tomography Imaging of Filtering Blebs after Deep Sclerectomy with Esnoper-Clip Implant: One-year Follow-up. J Curr Glaucoma Pract 2014;8(3):91-95.
منابع مشابه
Ultrasound biomicroscopy and optical coherence tomography imaging of filtering blebs after deep sclerectomy with new collagen implant.
PURPOSE To identify the clinical and anatomic characteristics of filtering blebs after glaucoma surgery with a new biodegradable collagen implant, Ologen, using ultrasound biomicroscopy (UBM) and Visante anterior segment optical coherence tomography (OCT). METHODS The authors conducted a prospective interventional case series in 15 eyes with openangleglaucoma. The authors performed limbal-bas...
متن کاملDeep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes
PURPOSE To report the safety and the effectiveness of deep sclerectomy (DS) with a new nonabsorbable uveoscleral hema implant (Esnoper-Clip) designed to increase trabecular and uveoscleral outflow and to achieve higher intrascleral blebs. MATERIALS AND METHODS Twenty-seven eyes of 27 patients with open-angle glaucoma, who underwent DS with an Esnoper-Clip implant, were included in this study....
متن کاملAnterior Segment Optical Coherence Tomography Imaging of Conjunctival Filtering Blebs after Glaucoma Surgery
Time domain (TD) and spectral domain (SD) optical coherence tomography (OCT) are cross-sectional, noncontact, high-resolution diagnostic modalities for posterior and anterior segment (AS) imaging. The AS-OCT provides tomographic imaging of the cornea, iris, lens, and anterior chamber (AC) angle in several ophthalmic diseases. In glaucoma, AS-OCT is utilized to evaluate the morphology of AS stru...
متن کاملAnalysis of Bleb Morphology After Trabeculectomy with Anterior Segment Optical Coherence Tomography
TITLE: Analysis of bleb morphology after trabeculectomy with anterior segment optical coherence tomography. PURPOSE: To describe the use of Anterior segment optical coherence tomography (AS OCT ) in imaging of trabeculectomy bleb to find out the morphology and internal structure, and correlate its internal characteristics with the function of the bleb. METHODS: Observational case-series study.6...
متن کاملA New Implant for Deep Sclerectomy: Esnoper®
Newer non-reabsorbing implants have been developed to maintain the hypotensor effect of nonpenetrating deep sclerectomy. In this article the authors discuss a new non-reabsorbing implant with 2-hydroxyethyl methacrylate (Esnoper®, AJL Ophthalmics, SA, Miñano, Alava, Spain), its design, technique of implantation and the available scientific evidence.
متن کامل