Sensitivity of inferior colliculus neurons to interaural time differences in the envelope versus the fine structure with bilateral cochlear implants.
نویسندگان
چکیده
Bilateral cochlear implantation seeks to improve hearing by taking advantage of the binaural processing of the central auditory system. Cochlear implants typically encode sound in each spectral channel by amplitude modulating (AM) a fixed-rate pulse train, thus interaural time differences (ITD) are only delivered in the envelope. We investigated the ITD sensitivity of inferior colliculus (IC) neurons with sinusoidally AM pulse trains. ITD was introduced independently to the AM and/or carrier pulses to measure the relative efficacy of envelope and fine structure for delivering ITD information. We found that many IC cells are sensitive to ITD in both the envelope (ITD(env)) and fine structure (ITD(fs)) for appropriate modulation frequencies and carrier rates. ITD(env) sensitivity was generally similar to that seen in normal-hearing animals with AM tones. ITD(env) tuning generally improved with increasing modulation frequency up to the maximum modulation frequency that elicited a sustained response in a neuron (tested </=160 Hz). ITD(fs) sensitivity was present in about half the neurons for 1,000 pulse/s (pps) carriers and was nonexistent at 5,000 pps. The neurons that were sensitive to ITD(fs) at 1,000 pps were those that showed the best ITD sensitivity to low-rate pulse trains. Overall, the best ITD sensitivity was found for ITD contained in the fine structure of a moderate rate AM pulse train (1,000 pps). These results suggest that the interaural timing of current pulses should be accurately controlled in a bilateral cochlear implant processing strategy that provides salient ITD cues.
منابع مشابه
Title: Sensitivity of Inferior Colliculus Neurons to Interaural Time Differences in the Envelope versus the Fine Structure with Bilateral Cochlear Implants
Bilateral cochlear implantation seeks to improve hearing by taking advantage of the binaural processing of the central auditory system. Cochlear implants typically encode sound in each spectral channel by amplitude modulating (AM) a fixed-rate pulse train, thus interaural time differences (ITD) are only delivered in the envelope. We investigated the ITD sensitivity of inferior colliculus (IC) n...
متن کاملInteraural time sensitivity dominated by cochlea-induced envelope patterns.
To localize sounds in space, humans heavily depend on minute interaural time differences (ITDs) generated by path-length differences to the two ears. Physiological studies of ITD sensitivity have mostly used deterministic, periodic sounds, in which either the waveform fine structure or a sinusoidal envelope is delayed interaurally. For natural broadband stimuli, however, auditory frequency sele...
متن کاملSensitivity to interaural time differences in the inferior colliculus with bilateral cochlear implants.
Bilateral cochlear implantation attempts to increase performance over a monaural prosthesis by harnessing the binaural processing of the auditory system. Although many bilaterally implanted human subjects discriminate interaural time differences (ITDs), a major cue for sound localization and signal detection in noise, their performance is typically poorer than that of normal-hearing listeners. ...
متن کاملEffects of reverberation on the directional sensitivity of auditory neurons across the tonotopic axis: influences of interaural time and level differences.
In reverberant environments, acoustic reflections interfere with the direct sound arriving at a listener's ears, distorting the binaural cues for sound localization. We investigated the effects of reverberation on the directional sensitivity of single neurons in the inferior colliculus (IC) of unanesthetized rabbits. We find that reverberation degrades the directional sensitivity of single neur...
متن کاملNeural coding of ITD with bilateral cochlear implants: Effects of auditory experience
Human bilateral cochlear implant users do poorly on tasks involving interaural time differences (ITD), a cue which provides important benefits to the normal hearing, especially in challenging acoustic environments. Yet the precision of neural ITD coding in acutely-deafened, bilaterallyimplanted cats is essentially normal (Smith and Delgutte, 2007). One explanation for this discrepancy is that n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neurophysiology
دوره 99 5 شماره
صفحات -
تاریخ انتشار 2008