Influence of liquid and gas flow rates on sulfuric acid mist removal from air by packed bed tower
نویسندگان
چکیده
The possible emission of sulfuric acid mists from a laboratory scale, counter-current packed bed tower operated with a caustic scrubbing solution was studied. Acid mists were applied through a local exhaust hood. The emissions from the packed bed tower were monitored in three different categories of gas flow rate as well as three liquid flow rates, while other influencing parameters were kept almost constant. Air sampling and sulfuric acid measurement were carried out iso-kinetically using USEPA method 8. The acid mists were measured by the barium-thorin titration method. According to the results when the gas flow rate increased from 10 L/s to 30 L/s, the average removal efficiency increased significantly (p < 0.001) from 76.8 ± 1.8% to 85.7 ± 1.2%. Analysis of covariance method followed by Tukey post-hoc test of 92 tests did not show a significant change in removal efficiency between liquid flow rates of 1.5, 2.5 and 3.5 L/min (p = 0.811). On the other hand, with fixed pressure loss across the tower, by increasing the liquid/gas (L/G) mass ratio, the average removal efficiency decreased significantly (p = 0.001) from 89.9% at L/G of <2 to 83.1% at L/G of 2-3 and further to 80.2% at L/G of >3, respectively. L/G of 2-3 was recommended for designing purposes of a packed tower for sulfuric acid mists and vapors removal from contaminated air stream.
منابع مشابه
CO2 Removal from Air in a Countercurrent Rotating Packed Bed, Experimental Determination of Height of Transfer Unit
Carbon dioxide capture is a key issue in climate change mitigation. For decades the removal of carbon dioxide has been an essential step in many industrial processing operations such as the synthesis of ammonia, natural gas purification, and oil refining. In this study, a rotating packed bed has been designed for absorption of carbon dioxide from an air stream. The rotating packed bed is a comp...
متن کاملRemoval of air ammonia in a spray tower by dilute sulfuric acid solution
Introduction: Workplace air quality is a very important factor in community health and is measured by measuring and evaluating airborne contaminants. One of these airborne pollutants is ammonia gas. Spray towers are important components of air pollution control. The aim of this study was to investigate the effects of using diluted sulfuric acid solution on the efficiency of ammonia removal in a...
متن کاملمقایسه میزان حذف آمونیاک از هوا توسط شستشودهنده تر پر شده با حلقههای راشیگ سرامیکی و پی وی سی
Background: Different packing materials are used in wet scrubbers that each one has its own advantages and limitations. Common ceramic packing materials have high removal efficiency but they are heavy, fragile and high head loss along the bed. Finding a suitable replacement for these materials has always been concerned by researchers. The objective of the present study was to compare the ...
متن کاملاثر تعداد نازل، تراکم گاز آمونیاک و فشار مایع شستشو دهنده آب بر کارایی حذف گاز آمونیاک در هوا در یک برج پاشنده
Background and aims: Spray tower is a cost effective and simple equipment for ammonia gas purification. But its’ appropriate performance in the removal of ammonia gas is under question. In this study, the effect of nozzle number, concentration of input ammonia gas and scrubbing liquid pressure over the removal efficiency of spray tower was studied. Methods: In present study, a spra...
متن کاملمطالعه آزمایشگاهی استفاده از میدانهای آکوستیکی با تراز فشار صوت بالا در حذف میستهای اسیدسولفوریک از جریان هوا
Background and aims: Development of new air pollution control techniques have always been the main concern of the researchers. The purpose of this experimental study was to investigate the effects of using acoustic fields at high sound pressure levels on the removal of sulfuric acid mist from the air stream. Methods: In this experimental study, an experimental scale agglomeration chamber was...