STRESS ERRORS ASSOCIATED WITH MINIATURIZATION OF psi ASSEMBLY X-RAY STRESS ANALYZERS

نویسنده

  • Toru GOTO
چکیده

Using a model and a simulation method, the problems caused by miniaturization of goniometers are discussed from the viewpoint of the stress error caused by systematic errors including the mis-setting of the specimen and the misalignments of the collimator and detector of the Ψ assembly X-ray stress analyzer with a position sensitive detector. As a concluion, it was found that stress errors increase with decreasing goniometer size, and it is believed that the goniometer size could be optimized by the approach adopted in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stress Errors Associated with Miniaturization of X-Ray Stress Analyzer

The problems caused by miniaturization of the goniometer are discussed from the viewpoint of the stress error caused by mis-setting of the specimen and misalignment of the collimator and detector for the Q assembly X-ray stress analyzer using a position sensitive detector. The stress errors were calculated using a model and a simulation method. It was found that they tend to increase with the d...

متن کامل

The Influence of Effective Factors on Mechanical Stress on Fingertips During Snap-fit Assembly

Objectives: Nowadays, Snap-fits are used in the automotive industry as a proper alternative for mechanical joints, cabling joints, and car interior lining joints. Due to the special form of these joints, which are assembled manually, the contact area between Snap-fits and the worker’s fingertips can be too small. This can cause skin pain on the worker’s  fingertips. Therefore, ...

متن کامل

Determination of Residual Stress of PACVD Nanostructure TiN Coatings by GIXRD Method

In this study, thin layers of titanium nitride (TiN) were deposited on H13 steel substrates at different duty cycles and temperature of 520 ˚C using plasma assisted chemical vapor deposition (PACVD). Uniaxial residual stress was calculated by X-ray diffraction (XRD) and Sin2 Ψ method. Then the residual stress of the samples were measured by Grazing Incidence X-ray Diffraction (GIXRD) method and...

متن کامل

Experimental and Numerical Study of Residual Stress in the WC-12Co HVOF Sprayed Coatings

Thermally sprayed coatings are intrinsically associated with residual stresses in the deposits. These stresses are varied in nature and magnitude, and have a pronounced effect on the mechanical behavior of the system. In the current study, WC-12Co coatings were deposited using HVOF thermal spraying. The sin2ψ method was used to evaluate the through thickness residual stress by means ...

متن کامل

بررسی روایی و اعتبار فرم کوتاه شاخص استرس فرزندپروری (PSI-SF)

This study was done to investigate the validity and reliability of Persian version of the Parenting Stress Index - Short Form (PSI-SF) among fathers of normal child under 7 years old. This study was descriptive and in type of psychometric. 100 persons among fathers of preschool children were selected randomly as sample in Isfahan, and they answered to the questionnaire. Data obtained were anal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004