Intra-ocular lens power calculation in patients with high axial myopia before cataract surgery.
نویسندگان
چکیده
PURPOSE To evaluate the accuracy of different formulas used for IOL power calculation in patients with high axial myopia undergoing cataract surgery. METHODS A prospective clinical study was carried out on 53 eyes of 51 patients with an axial length from 25.5 to 31.4 mm including 21 males (41.2%) and 30 females (58.8%). Calculation of the IOL power to be implanted was done by three available IOL power formulas; Haigis formula, SRK/T formula, and Holladay I formula. The mean error (ME) was calculated from the difference between the formula predicted refractive error and the actual post operative refractive error. RESULTS There was no statistically significant difference between the mean error of the three formulas used in the overall performance or in the axial length subcategories. SRK/T formula caused the smallest mean error, (+0.17 D). Haigis formula showed a higher ME (+0.21 D) and Holladay formula caused a myopic postoperative refractive error (-0.20 D). CONCLUSION The calculation of IOL power in patients with high axial myopia using the third or the fourth generation formulas help in improvement of the accuracy of the calculation and decreasing the post operative refractive error. SRK/T formula showed the lowest mean error, however, there was not statistically significant difference between the three formulas used, neither in the overall performance, nor in axial length subcategories.
منابع مشابه
Biometric parameters and intra ocular lens power used for cataract eyes in Karnali, Nepal.
INTRODUCTION The biometric parameters of the eye are measured for the calculation of the intra ocular lens power to be used in cataract surgery. OBJECTIVE To report the keratometry reading, axial length and intra ocular lens power used for eyes operated for cataract in Karnali Zone, Nepal, and to compare these findings with those reported in other similar studies. SUBJECTS AND METHODS The d...
متن کاملThe Comparative Study of Refractive Index Variations between Haigis, Srk/T and Hoffer-Q Formulas Used for Preoperative Biometry Calculation in Patients with the Axial Length >25 mm
BACKGROUND To compare refractive index variation between Hoffer-Q, Haigis and SRK/T formulas used for preoperative biometry calculation in patients with axial length >25 mm, undergoing cataract surgery. MATERIALS AND METHODS This is a randomized clinical trial study was performed on 54 eyes of 54 patients with ages of 40-70 years old and axial length >25 mm classified into three groups that t...
متن کاملAxial length , anterior chamber depth and lens thickness : Their intercorrelations in black South Africans
The ability to obtain accurate measurement of ocular biometric dimensions, such as axial length (AL), anterior chamber depth (ACD) and crystalline lens thickness (LT), is essential in many clinical and research applications. For example, AL is used clinically for intraocular lens (IOL) power calculation prior to cataract and refractive surgery1 and to diagnose ocular conditions such as staphylo...
متن کاملVisual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus
Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society
دوره 24 3 شماره
صفحات -
تاریخ انتشار 2010