STATEMENT OF PROBLEM The specific degree of retention for overdenture attachments is unknown in relation to design, location, and alignment to supporting dental implants. PURPOSE The purpose of this study was to evaluate the initial retention characteristics of 5 implant maxillary overdenture designs under in vitro dislodging forces. MATERIAL AND METHODS A simulated edentulous maxilla was fabricated with 4 screw-type 3.75 x 13-mm implants anteriorly. Five overdenture designs with the following attachments were evaluated: 4 plastic Hader clips with an EDS bar; 2 plastic anterior Hader clips with an identical EDS bar; 2 Hader clips with 2 posterior ERA attachments; 3 Zaag attachments on a bar; and 4 Zaag attachments with no bar. Overdentures were fabricated with full palatal coverage. Each design was subjected to 10 consecutive retention pulls on a universal testing machine. Data were subjected to analysis of variance and t tests to determine differences. RESULTS The highest average value after 10 pulls was 19.8 lb for the combination ERA and Hader clip design. The lowest retentive values were recorded for the 2 and 4 Hader clip designs (5.08 +/- 0.89 lb and 5.06 +/- 0.67 lb, respectively). Retention decreased over the course of consecutive pulls for all designs, especially for the most retentive designs. The smallest retention decrease occurred with the least retentive designs. CONCLUSION The results of this in vitro study suggest that the precise selection and placement of attachments may affect the clinical success of maxillary implant-retained overdentures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of guide planes and implant supported bar overdentures: a case report.

A stable occlusal plane is achieved with the combination of two maxillary, implant-supported milled bars securing an overdenture and bilateral, mandibular-fixed partial dentures. Overdenture retention is enhanced with attachments. Guide planes assure proper alignment of the overdenture for easy patient insertion and improved prosthesis stability. A reliable technique for verifying the accuracy ...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

Implant Retained Overdenture Improves the Retention and Stability by Using a Locator System in a Mandibular Edentulous patient: A Case Report

Abstract Complete maxillary and mandibular dentures have been used as a conventional treatment of edentulous patients for longer than a century. Suitable complete maxillary dentures are usually well tolerated but many patients struggle to chew and swallow with the complete mandibular denture because it is too unstable. Previous studies have shown that a mandibular two-implant retained overdentu...

متن کامل

Comparison of stress distribution around implants with two different attachments in overdenture supported by four maxillary implants (FEA method)

As a general rule, the purpose of treatment planning should be minimization and evenly distribution of mechanical stress in the adjacent implant and bone system. Various experimental studies have examined the distribution of stress in the implant supporting bones, thus avoiding the dangers involved. But there is still controversy about biomechanical effects and stress distribution in different ...

متن کامل

Comparison of prefabricated and custom-made bars used for implant-retained mandibular complete overdentures.

PURPOSE To compare prefabricated and custom-made bars used for implant-retained mandibular complete overdentures. MATERIALS Ten completely edentulous patients were selected for replacement with dental implants. Each patient received 2 (press-fit) dental implants, 1 implant on each side in the canine regions of the mandible. The implants were left submerged (unloaded) for a healing osseointegr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 86 6  شماره 

صفحات  -

تاریخ انتشار 2001