Interrupter resistance changes in children with bronchiolitis.

نویسندگان

  • Ozge Yilmaz
  • Ayhan Sogut
  • Senem Alkan
  • Hasan Yuksel
چکیده

INTRODUCTION Determination of lung function in children younger than three years with bronchiolitis may aid in treatment; however, technical difficulties such as requirement of sedation and lack in standardization limit clinical use. OBJECTIVES Aim of this study was to evaluate lung function changes using the interrupter technique in unsedated wheezing children younger than 3 years during and after acute bronchiolitis. METHODS Children with acute bronchiolitis younger than three years age were enrolled in this cohort study. Number of previous bronchiolitis episodes, severity of pulmonary findings, duration of acute bronchiolitis findings before presentation, requirement for hospitalization were recorded during initial enrollment. Duration of the current bronchiolitis was recorded. Interrupter resistance (Rint) measurements were performed on all children during and after bronchiolitis, using a face mask. RESULTS Mean (+/-SD) age of the children enrolled was 9.4 +/- 2.9 months. Mean bronchiolitis score was 5.6 +/- 1.4 at presentation. Mean duration of acute bronchiolitis before and after presentation were 10.1 +/- 13.0 and 5.1 +/- 2.3 days, respectively. There was a significant decrease in expiratory Rint values after clinical bronchiolitis findings terminated [1.08 (0.45) vs. 0.80 (0.33) kPa.L-1.s, p = 0.009]. Flow had not changed significantly while mouth pressure had decreased (p = 0.96 and p = 0.01, respectively). CONCLUSION Interrupter technique measurements showed higher resistance during acute bronchiolitis in children, which decreased after acute findings, disappeared. Rint may be used as a method to detect the change in airway function in unsedated children younger than three years in ambulatory conditions, despite some limitations of standardization in this age group.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interrupter resistance and oxygen saturation for methacholine challenge in young children

Inspiratory Rint better detects BHR than expiratory Rint and might better match PD20PtcO2 changes http://ow.ly/TrMvB.

متن کامل

Traffic-related air pollution is related to interrupter resistance in 4-year-old children.

Outdoor air pollution has been associated with decrements in lung function and growth of lung function in school-age children. Lung function effects have not been examined in preschoolers, with the exception of one study on minute ventilation in newborns. Our goal was to assess the relationship between long- and short-term exposure to traffic-related air pollution and interrupter resistance in ...

متن کامل

A portable device based on the interrupter technique for measuring airway resistance in preschool children.

The interrupter technique for measuring airway resistance is a noninvasive method reported to require minimal subject cooperation. Therefore it has a good potential for use in young children who are not able to cooperate with conventional lung function tests. The interrupter method is based on transient interruption of airflow at the mouth for a brief period during which alveolar pressure equil...

متن کامل

A portable device based on the interrupter technique to measure bronchodilator response in schoolchildren.

A new device for measuring airway resistance following brief airflow interruption (Microlab 4000; Micromedical Ltd, UK) was evaluated in 25 asthmatic school children in comparison with well-established methods. Airway resistance was measured during brief airflow interruption (Rint), before and after administration of salbutamol 200 micrograms by metered-dose inhaler, and in the spirometric para...

متن کامل

Measurements of interrupter resistance: reference values for children 3-13 yrs of age.

The interrupter technique is a convenient and sensitive technique for studying airway function in subjects who cannot actively participate in (forced) ventilatory function tests. Reference values for preschool children exist but are lacking for children >7 yrs. Reference values were obtained for expiratory interrupter resistance (R(int,e)) in 208 healthy Dutch Caucasian children 3-13 yrs of age...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pneumologia

دوره 61 4  شماره 

صفحات  -

تاریخ انتشار 2012