Titanium Coating of the Boston Keratoprosthesis

نویسندگان

  • Borja Salvador-Culla
  • Kyung Jae Jeong
  • Paraskevi Evi Kolovou
  • Homer H. Chiang
  • James Chodosh
  • Claes H. Dohlman
  • Daniel S. Kohane
چکیده

PURPOSE We tested the feasibility of using titanium to enhance adhesion of the Boston Keratoprosthesis (B-KPro), ultimately to decrease the risk of implant-associated complications. METHODS Cylindrical rods were made of poly(methyl methacrylate) (PMMA), PMMA coated with titanium dioxide (TiO2) over a layer of polydopamine (PMMATiO2), smooth (Ti) and sandblasted (TiSB) titanium, and titanium treated with oxygen plasma (Tiox and TiSBox). Topography and surface chemistry were analyzed by scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS). Adhesion force between rods and porcine corneas was measured ex vivo. Titanium sleeves, smooth and sandblasted, were inserted around the stem of the B-KPro and implanted in rabbits. Tissue adhesion to the stem was assessed and compared to an unmodified B-Kpro after 1 month. RESULTS X-ray photoelectron spectroscopy demonstrated successful deposition of TiO2 on polydopamine-coated PMMA. Oxygen plasma treatment did not change the XPS spectra of titanium rods (Ti and TiSB), although it increased their hydrophilicity. The materials did not show cell toxicity. After 14 days of incubation, PMMATiO2, smooth titanium treated with oxygen plasma (Tiox), and sandblasted titanium rods (TiSB, TiSBox) showed significantly higher adhesion forces than PMMA ex vivo. In vivo, the use of a TiSB sleeve around the stem of the B-KPro induced a significant increase in tissue adhesion compared to a Ti sleeve or bare PMMA. CONCLUSIONS Sandblasted titanium sleeves greatly enhanced adherence of the B-KPro to the rabbit cornea. This approach may improve adhesion with the donor cornea in humans as well. TRANSLATIONAL RELEVANCE This approach may improve adhesion with donor corneas in humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biocompatibility and biofilm inhibition of N,N-hexyl,methyl-polyethylenimine bonded to Boston Keratoprosthesis materials.

The biocompatibility and antibacterial properties of N,N-hexyl,methyl-polyethylenimine (HMPEI) covalently attached to the Boston Keratoprosthesis (B-KPro) materials was evaluated. By means of confocal and electron microscopies, we observed that HMPEI-derivatized materials exert an inhibitory effect on biofilm formation by Staphylococcus aureus clinical isolates, as compared to the parent poly(m...

متن کامل

Delayed Boston Keratoprosthesis Exchange due to a Preceding Vitreoretinal Surgery with Intraoperative Choroidal Detachment.

PURPOSE The aim is to describe the main characteristics of an anterior/posterior segment surgery and how to resolve intraoperative complications. Setting/Venue: The anterior and posterior segment surgical video was created at the Department of Ophthalmology, Virgin Macarena University Hospital, Seville, Spain. METHODS We present the case of a male with Stevens-Johnson syndrome and severe limb...

متن کامل

Results with the Boston Type I keratoprosthesis after Acanthamoeba keratitis

Purpose To report the outcomes of implantation of the Boston Type I keratoprosthesis in three patients with Acanthamoeba keratitis (AK), a severe infection that can lead to significant visual loss. Observations Case series reporting three patients with difficult cases of AK that needed multiple corneal transplantations and glaucoma surgeries. All patients were implanted with the Boston Type I...

متن کامل

Boston type 1 keratoprosthesis: the university of california davis experience.

PURPOSE To compare the University of California Davis experience using the Boston keratoprosthesis with the Boston Keratoprosthesis Study Group's initial report. DESIGN Retrospective chart review. PARTICIPANTS We analyzed 30 eyes of 28 patients who previously underwent Boston type 1 keratoprosthesis surgery at our institution between 2004 and 2008. METHODS Preoperative, intraoperative, an...

متن کامل

Treatment of Refractory Keratitis After a Boston Type I Keratoprosthesis With Corneal Collagen Cross-Linking.

PURPOSE To report a patient with refractory keratitis after a Boston type I keratoprosthesis treated with corneal collagen cross-linking (CXL). METHODS Case report. RESULTS A 29-year-old man with a history of chemical burn in the left eye underwent keratoprosthesis implantation. He developed infectious keratitis 4 months after surgery, which did not respond to topical antibiotics. The patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016