Characteristic Impedance, Power, and Causality

نویسنده

  • Dylan F. Williams
چکیده

A new causal power-normalized waveguide equivalent-circuit theory determines uniquely both the magnitude and phase of the characteristic impedance of a waveguide.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Causal Characteristic Impedance of Planar Transmission Lines

We compute power-voltage, power-current, and causal definitions of the characteristic impedance of microstrip and coplanar-waveguide transmission lines on insulating and conducting silicon substrates, and compare to measurement.

متن کامل

Causality and Waveguide Circuit Theory

We develop a new causal powernormalized waveguide equivalent-circuit theory that, unlike its predecessors, results in network parameters usable in both the frequency and time domains in a broad class of waveguides. Enforcing simultaneity of the voltages, currents, and fields and a power normalization fixes all of the parameters of the new theory within a single normalization factor, including b...

متن کامل

کنترل افتی-تطبیقی مبتنی بر امپدانس مجازی به منظور بهبود تسهیم توان راکتیو در ریزشبکه‌های اینورتری

With recent advances in power-electronics, inverter-based microgrids are gaining great attention. Droop control is one of the main methods to share the real and reactive power among distributed energy resources (DERs) in an islanded microgrids. Due to different characteristics of microgrid feeders, reactive power sharing is not fully accurate and consequently, some DERs may face overload. To ad...

متن کامل

Using a VIA-Less CRLH Transmission Line to Design Compact Wilkinson Power Dividers and Rat-Race Couplers

A method for design and implementation of a compact via-less Composite Right/Left-Handed Transmission Line (CRLH TL) is presented. By introducing a new circuit model, the CRLH transmission line behavior is studied versus the parameters variations to achieve the desired characteristic impedance and electrical length. Then a compact quarter wavelength CRLH transmission line with 70 Ω characte...

متن کامل

Effects of CT and VT Connection Point on Distance Protection of Transmission Lines with FACTS Devices

This paper presents the effects of instrument transformers connection points on the measured impedance by distance relays in the presence of Flexible Alternating Current Transmission System (FACTS) devices with series connected branch. Distance relay tripping characteristic itself depends on the power system structural conditions, pre-fault operational conditions, and especially the ground ...