Multiple ionization mass spectrometry strategy used to reveal the complexity of metabolomics.

نویسندگان

  • Anders Nordström
  • Elizabeth Want
  • Trent Northen
  • Janne Lehtiö
  • Gary Siuzdak
چکیده

A multiple ionization mass spectrometry strategy is presented based on the analysis of human serum extracts. Chromatographic separation was interfaced inline with the atmospheric pressure ionization techniques electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in both positive (+) and negative (-) ionization modes. Furthermore, surface-based matrix-assisted laser desorption/ionization (MALDI) and desorption ionization on silicon (DIOS) mass spectrometry were also integrated with the separation through fraction collection and offline mass spectrometry. Processing of raw data using the XCMS software resulted in time-aligned ion features, which are defined as a unique m/z at a unique retention time. The ion feature lists obtained through LC-MS with ESI and APCI interfaces in both +/- ionization modes were compared, and unique ion tables were generated. Nonredundant, unique ion features, were defined as mass numbers for which no mass numbers corresponding to [M + H](+), [M - H](-), or [M + Na](+) were observed in the other ionization methods at the same retention time. Analysis of the extracted serum using ESI for both (+) and (-) ions resulted in >90% additional unique ions being detected in the (-) ESI mode. Complementing the ESI analysis with APCI resulted in an additional approximately 20% increase in unique ions. Finally, ESI/APCI ionization was combined with fraction collection and offline-MALDI and DIOS mass spectrometry. The parts of the total ion current chromatograms in the LC-MS acquired data corresponding to collected fractions were summed, and m/z lists were compiled and compared to the m/z lists obtained from the DIOS/MALDI spectra. It was observed that, for each fraction, DIOS accounted for approximately 50% of the unique ions detected. These results suggest that true global metabolomics will require multiple ionization technologies to address the inherent metabolite diversity and therefore the complexity in and of metabolomics studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative quantitation in single-cell metabolomics by laser ablation electrospray mass spectrometry.

Single-cell analysis of metabolites by mass spectrometry (MS) is challenging due to the very limited volume and inherent molecular complexity of the sample. Quantitative metabolomic analysis of individual cells provides information on the metabolic heterogeneity of cells unattainable by aggregate analysis of multiple cells. Depending on the ionization method, MS can offer quantitative analysis ...

متن کامل

Analytical strategies for LC-MS-based targeted metabolomics.

Recent advances in mass spectrometry are enabling improved analysis of endogenous metabolites. Here we discuss several issues relevant to developing liquid chromatography-electrospray ionization-mass spectrometry methods for targeted metabolomics (i.e., quantitative analysis of dozens to hundreds of specific metabolites). Sample preparation and liquid chromatography approaches are discussed, wi...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Direct monitoring of chemical transformations by combining thin layer chromatography with nanoparticle-assisted laser desorption/ionization mass spectrometry.

A nanomaterial-assisted method that combines thin layer chromatography (TLC) with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) was developed to directly monitor chemical transformations. A substrate-dependent extraction strategy was studied and successfully used to identify target molecules from the depths of a developed TLC plate. By using this strategy, a hydrophob...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 80 2  شماره 

صفحات  -

تاریخ انتشار 2008