Cerebral haemodynamic physiology during steep Trendelenburg position and CO(2) pneumoperitoneum.
نویسندگان
چکیده
BACKGROUND The steep (40°) Trendelenburg position optimizes surgical exposure during robotic prostatectomy. The goal of the current study was to elucidate the influence of this patient positioning on cerebral blood flow and zero flow pressure (ZFP), and to assess the validity of different methods of evaluating ZFP. METHODS In 21 consecutive patients who underwent robotic endoscopic radical prostatectomy under general anaesthesia, transcranial Doppler flow velocity waveforms and invasive arterial and central venous pressure (CVP) waveforms suitable for analysis were recorded throughout the whole operative procedure in 14. The ZFP was determined by regression analysis of the pressure-flow plot and by different simplified formulas. The effective cerebral perfusion pressure (eCPP), pulsatility index (PI), and resistance index (RI) were determined. RESULTS While patients were in the Trendelenburg position, the ZFP increased in parallel with the CVP. The PI, RI, gradient between the ZFP and CVP, and the gradient between the CPP and the eCPP did not increase significantly (P<0.05) after 3 h of the steep Trendelenburg position. Using the formula described by Czosnyka and colleagues, the ZFP correlated closely with that calculated by linear regression throughout the course of the operation. CONCLUSIONS Prolonged steep Trendelenburg positioning and CO(2) pneumoperitoneum does not compromise cerebral perfusion. ZFP and eCPP are reliable variables for assessing brain perfusion during prolonged steep Trendelenburg positioning.
منابع مشابه
Influence of steep Trendelenburg position and CO(2) pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during robotic prostatectomy.
BACKGROUND The steep (40 degrees ) Trendelenburg position optimizes surgical exposure during robotic prostatectomy. The goal of the current study was to investigate the combined effect of this position and CO(2) pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during these procedures. METHODS Physiological data were recorded during the whole surgical procedure ...
متن کاملArterial to end-tidal carbon dioxide pressure gradient increases with age in the steep Trendelenburg position with pneumoperitoneum
BACKGROUND Several factors affect the end-tidal carbon dioxide pressure (P(ET)CO(2)) and increase the arterial to end-tidal carbon dioxide pressure gradient (P(a-ET)CO(2)) during general anesthesia. We evaluated the relationship between age and P(a-ET)CO(2) during pneumoperitoneum in the steep Trendelenburg position in patients undergoing robot-assisted laparoscopic prostatectomy (RALP). METH...
متن کاملCerebral Oxygenation during Laparoscopic Surgery: Jugular Bulb versus Regional Cerebral Oxygen Saturation
PURPOSE We hypothesized that regional cerebral oxygen saturation (rSO2) could replace jugular bulb oxygen saturation (SjvO2) in the steep Trendelenburg position under pneumoperitoneum. Therefore, we evaluated the relationship between SjvO2 and rSO2 during laparoscopic surgery. MATERIALS AND METHODS After induction of anesthesia, mechanical ventilation was controlled to increase PaCO2 from 35 ...
متن کاملThe effect of pneumoperitoneum and Trendelenburg position on respiratory mechanics during pelviscopic surgery
BACKGROUND Conventional pelviscopic surgery requires pneumoperitoneum with CO(2) gas insufflation and lithotomy-Trendelenburg position. Pneumoperitoneum and Trendelenburg position may influence intraoperative respiratory mechanics in anesthetic management. This study was conducted to investigate the influence of pneumoperitoneum and Trendelenburg position on respiratory compliance and ventilati...
متن کاملSonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position
BACKGROUND It remains to be elucidated whether the Trendelenburg position increases intracranial pressure (ICP). ICP can be evaluated by measuring the sonographic optic nerve sheath diameter (ONSD). We investigated the effect of the isolated Trendelenburg position on ONSD in patients undergoing robot-assisted laparoscopic radical prostatectomy. Additionally, we evaluated the effect of the Trend...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 108 3 شماره
صفحات -
تاریخ انتشار 2012