Consistent, multi-instrument single tube quantification of CD20 in antibody bound per cell based on CD4 reference.

نویسندگان

  • Heba Degheidy
  • Fatima Abbasi
  • Howard Mostowski
  • Adolfas K Gaigalas
  • Gerald Marti
  • Steven Bauer
  • Lili Wang
چکیده

Detecting changes in the expression levels of cell antigens could provide critical information for the diagnosis of many diseases, for example, leukemia, lymphoma, and immunodeficiency diseases, detecting minimal residual disease, monitoring immunotherapies and discovery of meaningful clinical disease markers. One of the most significant challenges in flow cytometry is how to best ensure measurement quality and generate consistent and reproducible inter-laboratory and intra-laboratory results across multiple cytometer platforms and locations longitudinally over time. In a previous study, we developed a procedure for instrument standardization across four different flow cytometer platforms from the same manufacturer. CD19 quantification was performed on three of the standardized instruments relative to CD4 expression on T lymphocytes with a known amount of antibody bound per cell (ABC) as a quantification standard. Consistent and reliable measures of CD19 expression were obtained independent of fluorochrome used demonstrating the utility of this approach. In the present investigation, quantification of CD20 relative to CD4 reference marker was implemented within a single tube containing both antibodies. Relative quantification of CD20 was performed using anti-CD20 antibody (clone L27) in three different fluorochromes relative to anti-CD4 antibody (clone SK3). Our results demonstrated that cell surface marker quantification can be performed robustly using the single tube assay format with novel gating strategies. The ABC values obtained for CD20 expression levels using PE, APC, or PerCP Cy5.5 are consistent over the five different instrument platforms for any given apparently healthy donor independent of the fluorochrome used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow Cytometer Performance Characterization, Standardization and Calibration against CD4 on T Lymphocytes Enables Quantification of Biomarker Expressions for Immunological Applications

There is an urgent need for developing a procedure for biomarker standardization and relative quantificationin clinical laboratories. Measuring the expression levels of cell antigens is critical for the diagnosis of many diseases, e.g. leukemia, lymphoma and immunodeficiency diseases. One of the most significant challenges in flow cytometry is obtaining inter-laboratory and intra-laboratory con...

متن کامل

تولید آنتی بادی تک زنجیره‌ای انسانی شده ضد مارکر CD20 در E.coli

Background and Objectives: Rituximab is an anti-CD20 chimeric monoclonal antibody widely used for the treatment of malignant B cells lymphoma. However, the immunogenicity of murine-derived monoclonal antibodies and the large size of full length antibodies restrict cancer immunotherapy. Humanized single chain antibodies can be a solution and a promising alternative for application in immunothera...

متن کامل

Construction and cloning of a recombinant expression vector containing human Cd20 Gene for antibody therapy in Non-Hodgkin Lymphoma

ABSTRACT Introduction: Non-Hodgkin lymphoma (NHL) is a cancer that starts in lymphocytes. The main treatment for NHL is chemotherapy and radiation. Today immunotherapy is a promising therapeutic approach in the treatment of a variety cancers which is high specific unlike previous methods. Antibodies do not penetrate effectively into tumore tissues because of their large size. Whe...

متن کامل

Quantification of Cells with Specific Phenotypes I: Determination of CD4+ Cell Count Per Microliter in Reconstituted Lyophilized Human PBMC Prelabeled with Anti-CD4 FITC Antibody

A surface-labeled lyophilized lymphocyte (sLL) preparation has been developed using human peripheral blood mononuclear cells prelabeled with a fluorescein isothiocyanate conjugated anti-CD4 monoclonal antibody. The sLL preparation is intended to be used as a reference material for CD4+ cell counting including the development of higher order reference measurement procedures and has been evaluate...

متن کامل

تولید انبوه آنتی‌بادی مونوکلونال علیه پپتید خارج سلولی CD20 و ارزیابی اتصال اختصاصی آن به سلول‌های بیان‌کننده CD20

   Background & Aims: Nowadays, by advent of hybridoma technology in monoclonal antibodies production various cell markers could be evaluated in malignant and non-malignant cells. CD20, non-glycosylated phosphoprotein is as an ideal marker in leukemia and B-cell lymphoma diagnosis which is expressed on more than 95% of normal and neoplastic B-cells except for early B-cells and mature plasma. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cytometry. Part B, Clinical cytometry

دوره 90 2  شماره 

صفحات  -

تاریخ انتشار 2016