Performance evaluation of automated immunoassays on the Technicon Immuno 1 system.

نویسندگان

  • M Letellier
  • A Lévesque
  • F Daigle
  • A Grant
چکیده

We performed an immunoassay evaluation for various analytes on a fully automated random-access analyzer, the Technicon Immuno 1 system from Bayer Corp. This system involves latex agglutination, magnetic separation sandwich, and magnetic separation competitive immunoassay configurations. The evaluated analytes were thyrotropin (TSH), triiodothyronine, thyroxine, free thyroxine, follitropin, lutropin, prolactin, beta subunit of human chorionic gonadotropin, cortisol, ferritin, alpha-fetoprotein, carcinoembryonic antigen, and prostate-specific antigen. We tested the assay precision, linearity, and correlation with comparison methods for these analytes. The functional sensitivity of the TSH assay and the sample-to-sample carryover were also studied. Excellent results were obtained for within-run and between-day precision studies, with most assays showing within-run CVs <4% and between-day CVs <6%. The linearity for all assays was acceptable and the correlation between Immuno 1 assays and comparison methods showed satisfactory results. The functional sensitivity of the TSH assay was estimated at 0.04 mU/L. No sample-to-sample carryover was detected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

Secure Bio-Cryptographic Authentication System for Cardless Automated Teller Machines

Security is a vital issue in the usage of Automated Teller Machine (ATM) for cash, cashless and many off the counter banking transactions. Weaknesses in the use of ATM machine could not only lead to loss of customer’s data confidentiality and integrity but also breach in the verification of user’s authentication. Several challenges are associated with the use of ATM smart card such as: card clo...

متن کامل

Performance evaluation of the croissant production line with reparable machines

In this study, the analytical probability models for an automated serial production system, bufferless that consists of n-machines in series with common transfer mechanism and control system was developed. Both time to failure and time to repair a failure are assumed to follow exponential distribution. Applying those models, the effect of system parameters on system performance in actu...

متن کامل

DIAGNOSTIC VALUE OF MEAN PEROXIDASE INDEX IN EARLY KAWASAKI DISEASE

The charts of 27 patients with Kawasaki disease (KD) admitted to Nemazee Hospital in Shiraz from January 1991 to October 1998 were reviewed to identify the results of mean peroxidase index (MPXI) values, a measure of neutrophil staining intensity, obtained by the Technicon HI analyzer (Technicon Instruments Corp., Tarrytown, NY) within the first 10 days of the illness 2 separate groups of ...

متن کامل

AGV (automated guided vehicle) robot: Mission and obstacles in design and performance

The AGV (automated guided vehicle) was introduced in UK in 1953 for transporting. But nowadays, due to their high efficiency, flexibility, reliability, safety and system scalability, they are used in various application in industries. In brief, the AGV robot is a system which typically made up of vehicle chassis, embedded controller, motors, drivers, navigation and collision avoidance sensors, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 42 10  شماره 

صفحات  -

تاریخ انتشار 1996