Lightning morphology and impulse charge moment change of high peak current negative strokes

نویسندگان

  • Gaopeng Lu
  • Steven A. Cummer
  • Richard J. Blakeslee
  • Stephanie Weiss
  • William H. Beasley
چکیده

[1] We have analyzed very high frequency lightning mapping observations and remote magnetic field measurements to investigate connections between lightning morphology and impulse charge moment change (iCMC) of negative cloud-to-ground (CG) strokes with high estimated peak currents. Four lightning morphologies are identified for a total of 2126 strokes within optimum detection range of the North Alabama Lightning Mapping Array, and statistical iCMC distributions are given for each of these types. Almost all (>90%) of the largest impulse charge moments (greater than 200 C km in this data set) are not produced by strokes in ordinary negative CG flashes. Instead, negative strokes with the largest iCMCs are almost exclusively associated with two unusual flash types that both initially develop as positive (normal) intracloud lightning. In the first type the negative stroke with high iCMCs results from a negative leader that descends from the midlevel negative charge region after the upper level negative leader ceases propagating. In the second type, the upper level negative leader of the intracloud lightning progresses toward ground as a so-called bolt from the blue to generate the negative stroke. Measurements of strokes associated with four negative polarity sprites suggest that all four were most likely produced in the first unusual lightning type. Our results highlight that estimated peak current and impulse charge transfer are not always well correlated and that the in-cloud lightning structure strongly influences charge transfer on short time scales in negative CG strokes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implications of lightning charge moment changes for sprite initiation

[1] We report impulse lightning charge moment changes (defined as occurring in the first 2 ms after return stroke onset) in all cloud-to-ground lightning strokes detected by the National Lightning Detection Network in three storms during which above-thunderstorm sprite video was recorded. After analyzing strokes that both did and did not produce sprites and carefully accounting for lightning-sp...

متن کامل

Charge moment change and lightning-driven electric fields associated with negative sprites and halos

[1] Sprites are structured high altitude optical emissions produced by lightning-driven electric fields. Both strong positive and negative cloud to ground flashes (CGs) are capable of initiating sprites. However, reported sprites are almost exclusively produced by +CGs. The very limited number of negative polarity sprites makes it difficult to reveal their morphologies and mechanisms. Since 200...

متن کامل

Sprite produced by consecutive impulse charge transfers following a negative stroke: Observation and simulation

On the morning of 5 June 2013, two cameras of the SpriteCam network concurrently captured a red sprite with diffuse halo over a mesoscale convective system (MCS) passing the panhandle area of Oklahoma. This sprite was produced by a negative cloud-to-ground (CG) stroke with peak current of!103 kA in amanner different from previous observations in several aspects. First of all, the causative stro...

متن کامل

Analysis of lightning strokes associated with sprites observed by ISUAL in the vicinity of North America

We examined the broadband (< 1 Hz to 30 kHz) lightning sferics associated with 395 sprites observed near North America by the Imager of Sprites and Upper Atmospheric Lightning (ISUAL) onboard the FORMOSAT-2 satellite in a 12-year period from 2004 2015. Our analysis indicates that the ISUAL dataset contains a significant fraction (69, or ~18%) of negative sprites, which were predominantly (> 80%...

متن کامل

Transient luminous events above two mesoscale convective systems: Charge moment change analysis

[1] Charge moment change (DMQ) data were examined for 41 positive cloud‐to‐ground (+CG) lightning discharges that were parents of transient luminous events (TLEs; mainly sprites) over two different storms: 9 May (20 parents) and 20 June 2007 (21). Data were broken down by contributions from the impulse DMQ (iDMQ), within the first 2 ms of the return stroke, and the DMQ from the continuing curre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012